Checking Battery Specific Gravity - Windsor Chariot 2 iVac 24 ATV CV2410125760 Operating Instructions Manual

Table of Contents

Advertisement

Maintenance

Checking Battery Specific Gravity

Use a hydrometer to check the battery specific gravity.
CHECKING GRAVITY
a. Hydrometer Battery
b. Battery
NOTE: Do not take readings immediately after adding
distilled water, if the water and acid are not thoroughly
mixed, the reading may not be accurate.
Check the hydrometer readings against this chart.
SPECIFIC GRAVITY
°
°
@ 80
F (27
C)
1.265
1.225
1.190
1.155
1.120
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80°F (27°C),
the reading must be temperature corrected.
To find the corrected specific gravity reading when the
temperature of the battery electrolyte is other than 80°F
(27°C): Add (+) to the specific gravity reading 0.004 (4
points), for each 10°F (6°C) above 80° (27°C). Subtract
(-) from the specific reading 0.004 (4 points), for each
10°F (6°C) below 80°F (27°C).
26
BATTERY CONDITION
100% CHARGED
75% CHARGED
50% CHARGED
25% CHARGED
DISCHARGED
86349370 Chariot iVac 24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chariot 2 ivac 24 atv cvc2410125770

Table of Contents