3.Securely fasten wires.
• Securely fasten wires to ceiling and
wall using insulated staples provided.
– Use insulated staples.
– Staples should be snug only.
• If rear cover is attached to power head,
remove it.
• On power head:
– Route wall button wires through wire guide on
power head.
– Split and strip ends of wire (Fig. 3-2 on
previous page).
– Insert wire into terminal holes and lightly press in
the orange locking clips above each terminal
hole. (You can use a pencil or small screwdriver
to comfortably press in locking clips.) The white
wire into #1 terminal hole and striped wire into
the #2 terminal hole.
– Confirm wire lock by lightly tugging on the wire.
The wire should remain in the terminal hole.
• Do NOT install rear cover yet.
4. Mounting.
• Fasten wall button to wall with 2 screws
(provided) (Fig. 3-4).
• Remove protective backing from "Entrapment"
warning label (Fig. 3-5). The "Entrapment" label
is located in the center of this manual.
– Stick label on wall near wall button.
16
Locking
Clips
6
5
Insulated
Staple
(Power Head With Rear Cover Removed)
FIG. 3-3 Insert wires
FIG. 3-4
FIG. 3-5
PN# 3642036534, 02/26/2010 REV. 1
wire guide
Terminal
Holes
4
3
2
1
6
5
4
3
2
+ –
P
Infrared Sensor
.
Mounting wall button.
Mounting Entrapment warning label.
1
B

Hide quick links: