Command Table - Icom IC-R6 Instruction Manual

Communications receiver
Hide thumbs Also See for IC-R6:
Table of Contents

Advertisement

11
CONTROL COMMAND

■ Command table

Sub
Cmd.
Data
Cmd.
00
see the right Send frequency data for transceive
01
02, 05, 06
03
see the right Read operating frequency
04
02, 05, 06
05
see the right Set operating frequency
06
02, 05, 06
11
00/10
12
00/01
14
01
see p. 66
03
see p. 66
15
01
00/01
02
see p.66
16
43
00, 01, 02
4B
00, 01, 02
65
Description
Send mode data for transceive
02=AM, 05=FM, 06=WFM
Read operating mode
02=AM, 05=FM, 06=WFM
Operating mode selection
02=AM, 05=FM, 06=WFM
Send/read the attenuator function
setting
00=OFF, 10=ON (approx. 10dB)
Send/read ANT selection
0.495 to 1.620 MHz band:
00=EXT, 01=BAR*
*"BAR" can only be selected in AM mode.
Other frequency band:
00=EXT, 01=EAR
Send/read the volume level
Send/read the squelch level
Read the squelch status
00=Squelch close, 01=Squelch open
Read the S-meter level
Send/read the tone squelch setting
00=OFF, 01=TSQL, 02=TSQL-R
Send/read the DTCS squelch setting
00=OFF, 01=DTCS, 02=DTCS-R
Sub
Cmd.
Data
Cmd.
16
4C
00/01
Send/read the VSC function setting
00=OFF, 01=ON
19
00
Read the receiver ID
1A
00
00/01
Send/read the AF filter setting
00=Filter OFF, 01=Filter ON
1B
01
see p. 66
Set/read TSQL tone frequency
02
see p. 66
Set/read DTCS code with polality
D Data content description
• Receive frequency (Command: 00, 03, 05)
q
w
X
X
X
X
X
When the tuning step is selected 8.33 kHz (Air band),
100 Hz digit, 10 Hz digit and 1 Hz digit can be set 3 or 6.
* 0: When 100 Hz digit is 0 or 5, 5: When100 Hz digit is 2 or 7
Description
e
r
t
X
X
X
X
X

Advertisement

Table of Contents
loading

Table of Contents