Pll And 5 - 2 Command - Icom IC-R10 Service Manual

Communications receiver
Hide thumbs Also See for IC-R10:
Table of Contents

Advertisement

5-1
PLL
AND BFO ADJUSTMENT
ADJUSTMENT
ADJUSTMENT
CONDITIONS
MEASUREMENT
VALUE
ADJUSTMENT
UNIT
LOCATION
UNIT
ADJUST
1ST
VCO
LOCK
VOLTAGE
1
Displayed frequency:
200
MHz
:
534
MHz
:
610
MHz
:
846
MHz
Receiving
MAIN
Connect a
voltmeter
(1
MQ
impedance)
to
the
check
point
LVI.
More
than
0.2
V
Verify
2
Displayed frequency:
533
MHz
:
609
MHz
:
845
MHz
:
895
MHz
Receiving
Less
than
3.3
V
2ND
VCO
LOCK
VOLTAGE
1
Displayed frequency:
100
MHz
Mode
:
SSB
Noise Blanker
:
ON
Receiving
MAIN
Connect
a
voltmeter
(1
MQ
impedance)
to
the
check
point
21
LV.
Less
than
2.5
V
Verify
2
Displayed frequency:
500
MHz
Receiving
More
than
0.6
V
3
Displayed frequency:
100
MHz
Mode
:
SSB
Noise Blanker
:
ON
Receiving
Connect
a
voltmeter
(1
MQ
impedance)
to
the
check
point
22
LV.
Less
than
2.5
V
4
Displayed frequency:
500
MHz
Receiving
More
than
0.6
V
1ST
REFERENCE
FREQUENCY
1
Displayed frequency:
Any
Mode
:
Any
Receiving
MAIN
Connect
a frequency
counter
to
the
check
point
REF.
10.24500
MHz
RF
C501
BFO
FREQUENCY
1
Displayed frequency:
144.0000
MHz
Mode
:
LSB
Receiving
LOGIC Connect
a
frequency
counter
to
the
check
point
CPI
.
453.500
kHz
LOGIC
R239
2
Mode
:
USB
Receiving
456.500
kHz
R243
5-1

Hide quick links:

Advertisement

Table of Contents
loading