TECHNICAL SPECIFICATION

Voltage: 220-240 V~ 50/60 Hz max. 10A
Absorbed power: 1350W
Pressure: 15 bar
Water tank capacity: 1,7 litres
Size: LxHxP: 272x374x441 mm
Weight: 11,4 Kg
The appliance complies with the following
EC directives:
Low Voltage Directive 2006/95/EC.
Directive EMC 89/336/EEC and subsequent
amendments 92/31/EEC and 93/68/EEC.
Materials and accessories coming into contact
with food conform to EEC directive 1935/2004.
ELECTRICAL CONNECTION (UK ONLY)
A)
If your appliance comes fitted with a plug, it will incorporate
a 13 Amp fuse. If it does not fit your socket, the plug should
be cut off from the mains lead, and an appropriate plug fit-
ted, as below.
WARNING: Very carefully dispose of the cut off plug after
removing the fuse: do not insert in a 13 Amp socket else-
where in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit
must be protected by a 15 Amp fuse.
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the
following code:
Green and yellow:
Blue:
Brown:
E
Earth
L
Neutral
N
Live

DISPOSAL

Important information for correct disposal
of the product in accordance with EC
Directive 2002/96/EC.
At the end of its working life, the product
must not be disposed of as urban waste. It must
be taken to a special local authority differentiated
waste collection centre or to a dealer providing
this service. Disposing of a household appliance
separately avoids possible negative consequences
for the environment and health deriving from
inappropriate disposal and enables the consti-
tuent materials to be recovered to obtain signifi-
cant savings in energy and resources.As a remin-
der of the need to dispose of household applian-
ces separately, the product is marked with a cros-
sed-out wheeled dustbin.
If the plug is a moulded-on type, the fuse cover must be re-
fitted when changing the fuse using a 13 Amp Asta approved
fuse to BS 1362. In the event of losing the fuse cover, the
plug must NOT be used until a replacement fuse cover can
be obtained from your nearest electrical dealer. The colour of
the correct replacement fuse cover is that as marked on the
base of the plug.
B)
If your appliance is not fitted with a plug, please follow the
instructions provided below:
As the colours of the wires in the mains lead may not correspond
with the coloured markings identifying the terminals in your plug,
proceed as follows:
The green and yellow wire must be connected to the terminal in
the plug marked with the letter E or the earth symbol
coloured green or green and yellow.
The blue wire must be connected to the terminal marked with the
letter N or coloured black.
The brown wire must be connected to the terminal marked with
the letter L or coloured red.