Gemini XGA-3000 Instruction Manual page 16

Xga-series amplifiers
Hide thumbs Also See for XGA-3000:
Table of Contents

Advertisement

Symptom
Cause
Unit does not produce sound.
• Power switch not in on position.
Power led does not light.
• Power cable not connected to amplifier or to outlet.
• AC outlet not active.
• Main amplifier fuse defective.
Power led lights, but no sound
• No input source signal.
is produced by the amplifier.
• Input source not connected.
• Input connecting cable defective.
• Speaker(s) not connected.
• Speaker cable defective.
• Speaker system(s) inoperative.
• Amplifier's level controls are set to zero.
Sound is present but volume
• Amplifier input level controls are set too low.
is too low even though source
• Wrong pin connections in cables.
device is set to a high level.
Loud 60 cycle hum is heard at
• Improper or defective ground connection at inputs.
all times through the speaker
• Improper or defective ground at input source device(s).
systems.
• Improper or defective ground connection on ac outlet.
• Ground loop through ac line connection/ rack mounting.
Sound is distorted.
• Distortion occurring in source device.
• Input level is set too high.
Protect led remains lit or goes
• Unit is operating at excessively high temperature.
on and off intermittently after
• Extremely low speaker impedance.
using amplifier for a short
• Short in speaker connectors, speaker cable or speaker
time.
system.
Fuse blows intermittently.
• Speaker load impedance is too low.
• Type or rating of the fuse is not correct.
Protect led(s) stay on with no
• Failed amplifier.
speakers connected and with
the amplifier cooled down.
Power led lights but there is
• Secondary DC fuses are blown (on either one or both
no sound from one or both
channels) indicating failed a failed channel or channels.
channels.
Solution
• Move power switch to on position.
• Connect power cable to ac supply.
• Check condition of outlet.
• Replace amplifier main power fuse on rear panel with correct type and rating.
• If the fuse blows a second time discontinue use and contact a qualified customer service technician
• Check for proper function of input source device.
• Check input cables and connections. Replace questionable cables with known good cables.
• Check speaker cables and connections. Replace questionable cables with known good cables.
• Check operating condition and status of speaker system(s).
• Be sure the level controls are properly set.
• Adjust level controls as per instructions.
• Use correct cables (as shown on back of unit).
• Check for proper ac line ground on power amp and all input devices.
• Check input cables for all source devices and signal processing as well as input cables to power
amplifier. Check position of ground lift switch as per instructions for lifting the ground.
• Never lift the AC line ground on the power amplifier. If you are not totally familiar with ground lift-
ing or unification procedures, do not attempt them without first consulting your dealer or a qualified
sound technician for more Information on grounding. Improperly done, such procedures can pose a
safety and/or fire hazard.
• Check clip indicators on input source devices and reset levels if necessary to eliminate distortion.
• Adjust level controls as per instructions.
• Check that amplifier is adequately ventilated on the front and rear panels where the air vents and
fans are located. If overheated, let the amplifier cool down before applying an input signal.
• Check the position of operation mode switch. Be sure that the speaker connections are made in
accordance with the switch setting.
• Verify speaker system impedances. Be sure the total speaker system impedance is at least 2 ohms
per channel when the operation mode switch is in the stereo position. If the switch is in the bridge
mode, the impedance must be at least 4 ohms. If you are not sure of your total speaker impedance
load, contact your dealer for more information.
• Check condition of speaker cables.
• If using bare wire connections on the outputs of the amplifier, be sure that no strands from one con-
nector are touching any other connector.
• Check for shorts on the outputs.
• Check your speaker impedance (info from dealer).
• Check that the fuse type and rating is correct.
• Contact the gemini customer service department or your authorized dealer to speak to a qualified
service technician.
• If only one channel fails, the second may still operate, but the unit should be serviced as soon as
possible. Contact the Gemini service department or your authorized dealer to speak to a qualified
customer service technician.
Solución de problemas • Dysfonctionnements • Fehlerbeseitigung
Troubleshooting
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xga-2000Xga-5000Xga-4000

Table of Contents