Appendix

System Settings (Parallel Connection)

❖ ❖ ❖ ❖ Parallel Timing
Specifies the timing for the parallel
interface. Normally, you do not
need to change this setting.
• ACK Inside
• ACK Outside
• STB Down
Note
❒ Default: ACK Outside
❖ ❖ ❖ ❖ Parallel Communication Speed
Spec ifie s t he co mmunicatio n
speed of the parallel interface. If
the speed is too high, data may not
be transferred smoothly. If this
happens, change the setting to
"Standard".
• High Speed
• Standard
Note
❒ Default: High Speed
8
❖ ❖ ❖ ❖ Selection Signal Status
Specifies the signal level of the par-
allel interface.
• High
• Low
Note
❒ Default: High
❖ ❖ ❖ ❖ Input Prime
Specifies whether the prime signal
is active or inactive when an input
prime signal is sent. Normally, you
do not need to change this setting.
• Effective
• Invalid
Note
❒ Default: Invalid
144
❖ ❖ ❖ ❖ Bidirectional Communication
Specifies, for instance, how a print-
er connected to the parallel inter-
face responds to a status request. If
you experience problems using an-
other manufacturer's printer, set
this to Off.
Limitation
❒ If set to Off, asynchronous com-
munication will not work.
• On
• Off
Note
❒ Default: On
❖ ❖ ❖ ❖ Signal Control
Specifies how to handle any errors
that occur when printing from a
computer. Normally, you do not
need to change this setting.
• Job Acceptance Priority
• Printer Priority
• Facsimile Priority
Note
❒ Default: Job Acceptance Priority