Installation; Installing The Fireplace Shell - Montigo H-Series DF Installation & Operation Manual

H-series df outdoor gas fireplace
Hide thumbs Also See for H-Series DF:
Table of Contents

Advertisement

H42DF-O Outdoor Gas Fireplace

Installing The Fireplace Shell

The fireplace may be installed in any location that maintains proper clear-
ances to air conditioning ducts, electrical wiring and plumbing. Safety,
as well as efficiency of operation, must be considered when selecting
the fireplace location. Try to select a location that does not interfere
with room traffic, has adequate ventilation, and offers an accessible
pathway for Direct Vent installation. Refer to page 4 - Vent Installation
for more information.
The fireplace dimensions are shown below:
25"
8"
5"
J
11 1/2
C L
C L
K
Top View
1 1/4
35 1/4
1 1/4
36 1/2
1
37 3/4
Front View
Figure 1. Fireplace dimensions.
Clearances
These clearances apply to all dimensions except the framed opening,
where the clearance to combustibles is 0". The H42DF-O clearance to
unprotected combustible walls which are perpendicular to the fireplace
opening, must not project beyond the shaded area shown in Fig. 24.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapor barrier. This will reduce
the possibility of a cold-air convection current on the fireplace.
Top - Rear Vent *
Top - Top Vent
Back
Sides
Floor
Mantle**
* Clearance from top of the Fireplace to a combustible ceiling within the fireplace
enclosure.
** Refer to Pages, 10 & 11.
Page 4

Installation

18 1/2"
1 1/4
18 1/2"
8"
5 1/2"
36 1/2
25 3/4
28 3/4
5 1/4"
Side View
H42DF-O
9"
17
1
/
2
1"
1"
0"
4"
Framing
46 3/8"
Figure 2. Framing dimensions.
48 1/8"
5"
Figure 3. Minimum Corner framing dimensions, using a 45° elbow.
When installing a shelf over the top of the fireplace, the following
guidelines must be adhered to: For Rear Vent applications the
minimum clearance from the top of the fireplace to a shelf is 9". For
Top Vent applications, the minimum clearance is 17 1/2". (Minimum
2" clearance must still be maintained around the vent pipes.)
Header
Shelf
10
40 1/8
33
Rear Vent
"
Figure 4. Framing for shelves over the fireplace.
When this appliance is installed directly on carpeting, tile or any
combustible material other than wood flooring, it must be installed
on a metal or wood panel extending the full width and depth of
the appliance.
* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"
37 3/4"
20 1/8"
42"
68"
MEL Short
Shelf
19
50 1/8
46 3/8
Top Vent
WARNING!
Header
46 3/8
Part No. XG0149