Panorama indoor residential gas fireplace (34 pages)
Summary of Contents for Montigo H34D
Page 1
Installation Operation & Maintenance H34D Gas Fireplace Warning: For Your Safety: Check local codes ■ Improper installation, adjustment, Do not store or use gasoline read alteration, service or maintenance can or other flammable vapors instructions prior to cause injury or property damage. Refer to and liquids in the vicinity of this manual.
Thank You for choosing a Montigo Gas Fireplace. About this Fireplace: Introduction ................2 The H34D is an 18,000 BTU fireplace with a pan-style burner and Installation glowing embers. This fireplace can be converted to both a Top Vent or Installing and Framing the Fireplace .......
These clearances apply to all dimensions except the framed opening, applications, the minimum clearance is 17 1/2". (Minimum where the clearance to combustibles is 0". The H34D clearances to 2" clearance must still be maintained around the vent pipes.) combustible materials are: Top - Rear Vent* 9"...
The fireplace gas connection and Use only certified Montigo vent components. (Use of other parts will void the the main operating gas valve is located behind the removable trim at the Montigo warranty, and may impede the operation of the fireplace.)
H34D Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations MTO-3F MTKOG Ensure that the two long mounting brackets are facing the bottom of the termination. (See inset). This will provide more heat protection at the top of the termination, where temperatures are highest.
Page 6
H34D Gas Fireplace Installation Converting to Top Vent/ Rear Vent H34DL Rear Vent H34DL Top Vent Use the following instructions to convert an H34DL for Top Vent use: Use the following instructions to convert an H34DL for Top Vent use: 1.
Top Vent Venting Runs Available Top Vent Components Before you install any venting, you must determine whether the venting The following venting components are available for the H34D Top run will be acceptable. Unacceptable venting can affect the fireplace's Vent: combustion.
H34D Gas Fireplace Installation Example 1: For our shortest venting configuration use components A and E (see Figure 9a). Figure 13. Extended Installation using a combination of solid and flex venting. Use the vent graph to determine your allowable Figure 11. Typical Top Vent installation. If the 90° elbow is installed run, then select appropriate components.
Page 9
H34D Gas Fireplace Installation B. Vertical (Through-The-Roof) Installations A maximum of two offsets (each offset has two 90° bends) may be ■ Vertical Terminations must be installed: made and shall not exceed total length of 25% of the vertical vent height, •...
H34D Gas Fireplace Installation Rear Vent Venting Runs 2. 45° Corner Installation. The H34DL Rear Vent has three possible installations which do not require vertical lift, all of these installations require that you install the Attach an EEL-45 (45° elbow) directly onto the flue collar. Cut the RHS101 heat sheild.
Page 11
B. Multi-Elbow Installations Installation Of Rear Vent DV For more diffiicult installation situations, the H34D Rear Vent may be H34D Rear Vent versions are supplied with an EXT-18 (female/female) installed with two — 90° elbows and up to 15' of horizontal run. If using section.
Wall Switch Switch tion, discoloration or premature failure of T.V. and radio components. Figure 25. Wiring for the H34D-I with Honeywell gas control and pilot. Painting: Special care is recommended by the Master Painters and Decorators Part No. XG0130 Page 12...
Removing and Installing Wiring for the optional Fan Kit the Door All H34D fireplaces may be equipped with optional fan kits for circulating heat into the living space. Removing the door: The door is held in place by a lip on the top of the metal frame and two Installations in Canada which employ the fans must be electrically buckles at the bottom.
H34D Gas Fireplace Installation Installing the Log Set Place the bottom left and right logs as shown below in figure 28d. Installing the Logs: Log 'D' Place the top left and right logs as shown in figure 28e. The H34DF is supplied with four ceramic fibre logs and a ceramic fibre logset base.
H34D Gas Fireplace Operation - Model H34D H34D with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Page 16
H34D Gas Fireplace Operation - Model H34D-I H34D-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Doors and logs can get very hot. Handle only when cool. The H34D is equipped with an adjustable burner, allowing you to raise or lower the flames. To adjust the flames, locate the black knob marked General 'Hi-Lo', in the centre of the gas control valve (See Figure 29).
H34D Gas Fireplace Maintenance Troubleshooting Gas Control Valve H34D-I HONEYWELL SV 9500 /SV9600 Power Generator Troubleshooting Sequence Pilot Adjustment Screw NOTE: Before Troubleshooting, Familiarize Yourself With Wall Switch The Startup And Checkout Procedure. START INSET CHECK: · Turn Gas Supply off ·...
The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten- year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs.
H34D Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, or M = clearance to mechanical air supply inlet balcony [16 inches (41 cm) minimum] [*6 feet (1.8 m) minimum] N = †...
Page 21
Test Connection Figure B1. Sit Nova 820 gas valve. H34D-MH Mobile Home The mobile home option is a factory installed on the H34D-MH gas Conversion Kits fireplace, and is for use in a manufactured or mobile home. The H34D-MH mobile home appliance is field convertible between The standard H34D or the H34D-I equipped with Hot Surface Natural Gas (NG) and Propane (LP).
Page 22
XG0130 Rev. 0 - 11/2003 Canadian Heating Products Inc. Montigo Del Ray Corp. Langley, BC V4W 4A1 Ferndale, WA 98248...