Door Name; Pin Reader Time Profile - Bosch K2200 Series User Manual

Readykey controllers
Table of Contents

Advertisement

K2200 Series | User Guide | 6.0
Table 17: Reader and Lock Operation Settings – Mode 1
Option
Type
7
PIN Reader with Time
Profiles
8
Not Used
Mode 2
Prompt:
Range:
Default:
Table 18: Reader and Lock Operation Settings - Mode 2
Option
Type
1
Request to Exit
Without Lock
Activation
2
Lock as Soon as
Possible
3
Log on Door Entry
Only
4 - 8
Not currently used.
6.1.5

Door Name

Prompt:
Default:
Use this field to give the door a useful name. This
name, which may contain up to 12 letters (A-Z),
numbers (0-9) and spaces (SPC), will appear on all
printed reports.
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
Installer Commands
Description
When set, this option allows people to use a door when their time profile has
expired. This would normally be the case for an exit door, where people would be
locked in they failed to leave before their time profile expired. An Exit out of
Hours report is generated when set.
No Readykey PIN reader with time profiles fitted
Unset
Set
Readykey PIN reader with time profiles fitted.
Only use this option if a Readykey PIN reader with time profiles is fitted to the reader
channel. Do not set this option if any other type of PIN reader is fitted. You cannot
have both option 5 (alarm module) and a PIN reader with time profiles set on the
same channel.
Leave Unset
M2
8 options
All unset
Description
Unset
RTE with Lock Output (normal operation)
Set
E with no Lock Output
This option is designed for use on the secure side of a door where exit is via a handle
etc. Pressing the Request to Exit switch simply informs the system that someone has
left the area
Unset
Lock release time operates normally
Set
Lock de-activated a maximum of 2 seconds after the door is opened.
Unset
All events are logged
Set
Events only logged if the door is opened
When set, if a key is presented to a door but the door isn't opened, the event will not
be logged.
ID
DOOR
n
n = 1 to 16
This option field controls an additional 8 different
settings of which only three are currently used,
controlling the operation of the reader and lock.
They are:
6.1.6

PIN Reader Time Profile

Prompt:
Range:
Default:
A PIN reader with time profiles provides two levels
of security. When the time profile is active, a valid
key alone will allow access, when the time profile is
inactive, a valid key plus the correct PIN is required.
If a time profile of 0 is used, a valid key plus PIN will
always be required.
An example may be a door that only requires a key
during normal office hours but requires a key plus
PIN at any other time.
EN | 44
PINTP
0 – 128
0

Advertisement

Table of Contents
loading

Table of Contents