What to do if a fault occurs

What to do if a fault occurs
The control unit has an advanced monitoring system that gives alarms if
anything unforeseen happens. Most alarms correct themselves. There is never a
risk of affecting something when you reset an alarm once or twice. In the event
of recurring alarms, contact your installer/service technician.
Example of an alarm:
When an alarm is triggered, an alarm window is displayed and a warning
signal sounds. The alarm window displays the alarm cause and the time and
date that the alarm occurred.
When you press the menu dial and Acknowledge is marked, the alarm
symbol disappears from the menu window and the alarm log, and the
warning signal is muted. The heat pump starts again within 15 minutes if
heating is required. If the fault has not been rectifi ed the lamp will remain
lit and the status LED will stop fl ashing red and will light red continuously.
Should several alarms have occurred on the heat pump, view the alarm log
where all alarms are listed. For active alarms, the alarm symbol is lit.

Dimmed menu display

Possible cause 1: Blown fuse in the house's fuse box/distribution box.
Action:
1. Check the fuses in the house's fuse box.
2. Replace the fuse / reset the circuit breaker if necessary.
3. The heat pump automatically returns to operating mode
Possible cause 2: Glass fuse in the hot water distribution unit has
blown.
Action:
1. Contact your installer.

Emergency operation

On top of the electric box of the hot water distribution unit, there is a switch that
lights green during normal operation. If a fault occurs in the control unit and
heating production stops, emergency operation can be activated manually using
the switch, which then goes out. See the user guide for the Greensource Hot
water distribution unit.
The additional electric heater takes over the heating production during
emergency operation. Heating can therefore be obtained until the installer or
authorised service technician has remedied the fault.
This function must not be confused with Alarm mode, which means that the
compressor stops, for safety, due to an active alarm. Heating production is still
controlled by the control unit.
within 15 minutes after the fault has been rectifi ed.
Alarm cause
Date when
the alarm
occurred
If you have deactivated the alarm
buzzer under Advanced menu no
warning signal is heard.
26
Time when the alarm occurred
Alarm symbol
Note

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensource 6 kwGreensource 7 kwGreensource 9.5 kw

Table of Contents