Hot Water Settings - Worcester GREENSOURCE User Manual

Air to water outdoor heat pump
Table of Contents

Advertisement

Hot water settings

The menus for hot water settings are only displayed when a hot water
heater is installed.
Extra hot water
You can obtain extra hot water by temporarily increasing the temperature of
the water in the hot water cylinder. A higher water temperature gives more
hot water when, for example, several people wish to shower. The heat pump
uses additional electric heater to increase the temperature to the desired
value, see point 5. The function Extra hot water (number of hours) is also
available under Menu.
This is what to do:
1. Select Hot water in the advanced menu.
2. Select Extra hot water.
3. Set the number of hours that the function is to be active.
4. Select Save to save the change or Cancel to return without saving.
5.
Set the desired Stop temperature.
6. Select Save to save the change or Cancel to return without saving.
Read off the remaining time of Extra hot water by going toTimers.
Hot water peak
Recurring increase in the hot water temperature
The Hot water peak menu is used to set the interval for a recurring increase
in the hot water temperature. If, for example, you set the value seven days,
the temperature is increased once a week to approximately 65ºC. You can
also specify Start time for when the temperature increase is to start, factory
setting is 03:00.
Time control hot water
The Time control hot water function means that you can choose to com-
pletely disable hot water heating to save energy. This is primarily effective
when peak tariffs are charged. This is done in the same way as other heat
pump time controls.
When the set time has elapsed you
must repeat the setting to get extra hot
water again. You can also increase the
number of hours during an ongoing
Extra hot water period.
Time control hot water can impair
hot water production
21
Advanced menu
Note
Note
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensource 6 kwGreensource 7 kwGreensource 9.5 kw

Table of Contents