Page 5
6 Pin Power Connector
Yellow
Starter
Green
Heater
Red
12 power
Red
12 power
Blue
Ignition 1
White
Select Out 30amp output
14 Pin Connector
Yellow
Re-Arm
Red/White
3rd CH
Brown
Disarm
Orange
(-) Out
White/Blue
Horn
Black/White
Park Brake Negative Park Brake Input - Manual Transmission Models Only.
Purple
(+) Door
White
Park Lights Positive Park Light Output - 10 Amp Max.
Green/White
Hood Pin
Green
(-) Door
Black
Ground
Pink
Brake
Blue/White
Tach
Blue
Glow Plug
3 Pin Connector Red
Green
Lock
Red
12vlt Output
Blue
Door Unlock
Note: Do not use the center pin of this connector to power relay packs. Doing so will damage the
output. Always use a fused power source when installing relays for keyless entry.
4 Pin Connector Blue
Antenna/ Program Button Connector.
Jumper Selections
Position One Second Starter Output On the White Wire From The 6-Pin Connector.
Position Two Second Accessory Output On The White Wire From The 6-Pin Connector.
Position Three Second Ignition* Output On The White Wire From The 6-Pin Connector.
To change the jumper position you must first remove the access cover from the top of the module.
Remove the cover as shown in the diagram below. The access cover will slide out of its position
when pushed outwards from the center of the module.
The jumpers control the output on the white wire from the six pin harness. To change the output of
this wire, place the jumper in one of the following positions
30amp output
12volts during crank only.
30amp output
12volts in accessory off during start.
30amp input
Constant 12volt power at ignition harness.
30amp input
Constant 12volt power at ignition harness.
30amp output
12volts in ignition and start positions.
Selectable Output. See jumper diagram.
0.75sec Pulse With Lock And On Shutdown.
Trunk Release - Hold button #2 for 5 seconds
0.75sec Pulse With Unlock And Before Start.
(-)While Running / Negative While Locked *Starter Program Mode.
(-)Horn Honk Output *User Program Mode
Positive Door Input - Manual Trans And Alarm Units Only.
Negative Hood Pin Input - MUST BE CONNECTED!!
Negative Door Input - Manual Transmissions Only.
System Ground Input - MUST BE CONNECTED!!
Positive Brake Input - MUST BE CONNECTED!!
Tach Signal Input - MUST BE CONNECTED ON TACH MODELS!!
Programmable Input - DIESEL ONLY. * Starter Program Mode
Door Lock Output - Programmable - Menu 1 Setting 3.
Low current output for Voltage Inverter Only.
Door Unlock Output - Programmable - Menu 1 Setting 3.