3.3.4.2 ChartView™ Enablement (GTN 7XX Only)
The GTN 7XX can display Jeppesen charts using the optional
ChartView feature, which must be activated. Complete the
following procedure to reenable ChartView.
NOTE
This manual only describes the necessary steps to
reenable the ChartView feature for existing
installations. For first-time ChartView enablement,
refer to the GTN 6XX/7XX Part 27 AML STC IM, P/N
190-01007-B3.
1. Remove power from the GTN.
2. Remove the database SD card from the SD card slot
and insert the ChartView Enablement Card (P/N
010-00878-40) that was used during initial installation
of the feature.
3. Enter configuration mode on the GTN by applying
power to the GTN while holding the HOME key.
4. Go to the Charts page from the GTN Options page.
Touch the ChartView key.
5. When the ChartView feature is activated, the ChartView key will be lit green, as shown in
Figure 3-14.
NOTE
The ChartView feature enablement card should be provided to the customer after service
to the GTN has been completed.
GTN 6XX/7XX Part 27 AML STC Maintenance Manual
Page 3-10
Figure 3-14. Chart Configuration
Page
190-01007-B1
Rev. 1