Trigger[:Source]:External:delay:state; Trigger[:Source]:External:slope; Trigger[:Source]:External[:Source] - Agilent Technologies N5171B Command Reference Manual

X-series signal generators
Hide thumbs Also See for N5171B:
Table of Contents

Advertisement

:TRIGger[:SOURce]:EXTernal:DELay:STATe

Supported
N5172B/82B
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:DELay:STATe ON|OFF|1|0
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:DELay:STATe?
This command enables or disables the operating state of the external trigger delay function.
For setting the delay time, see
information on configuring an external source,
*RST
0
Key Entry
Ext Delay Off On

:TRIGger[:SOURce]:EXTernal:SLOPe

Supported
N5172B/82B
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:SLOPe POSitive|NEGative
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:SLOPe?
This command sets the polarity for an external trigger signal while using the continuous, single
triggering mode. To set the polarity for gating, see
The POSitive and NEGative selections correspond to the high (positive) and low (negative) states of
the external trigger signal. For example, when you select POSitive, the waveform responds (plays)
during the high state of the trigger signal. When the X- Series signal generator receives multiple
trigger occurrences when only one is required, the signal generator uses the first trigger and ignores
the rest.
For more information on configuring an external trigger source and to select external as the trigger
source, see
":TRIGger[:SOURce]" on page
*RST
NEG
Key Entry
Ext Polarity Neg Pos

:TRIGger[:SOURce]:EXTernal[:SOURce]

Supported
N5172B/82B
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal[:SOURce] EPT1|EPT2|
EPTRIGGER1|EPTRIGGER2
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal[:SOURce]?
This command selects which PATTERN TRIG IN connection the X- Series signal generator uses to
accept an externally applied trigger signal when external is the trigger source selection.
For more information on configuring an external trigger source and to select external as the trigger
source, see
":TRIGger[:SOURce]" on page
the User's Guide.
The following list describes the command choices:
EPT1
This choice is synonymous with EPTRIGGER1 and selects the PAT TRIG rear panel
connector.
Agilent X-Series Signal Generators SCPI Command Reference
":TRIGger[SOURce]:EXTernal:DELay" on page
see":TRIGger[:SOURce]" on page
":TRIGger:TYPE:GATE" on page
305.
305. For more information on the rear panel connectors, see
Dual ARB Subsystem–N5172B/82B ([:SOURce]:RADio:ARB)
306, and for more
Arb Commands
305.
304.
307

Hide quick links: