Detailed Specifications

Temperature Measurements
Temperature Range (not calibrated below -10 C)
Ti200, Ti300 .................................................... -20 °C to +650 °C
Ti400 ............................................................... -20 °C to +1200 °C
Accuracy ............................................................. 2 C or 2 % (whichever is greater) at
On-screen emissivity correction.......................... all models
On-screen reflected background
temperature compensation ................................. all models
On-screen transmission correction ..................... all models
Imaging Performance
Image Capture Frequency .................................. 9 Hz or 60 Hz refresh rate depending
Detector Type: Focal Plane Array, uncooled microbolometer
Ti400 ............................................................... 320 X 240
Ti300 ............................................................... 240 X 180
Ti200 ............................................................... 200 X 150
Thermal Sensitivity (NETD)
Ti400, Ti300 .................................................... ≤0.05 °C at 30 °C target temp (50 mK)
Ti200 ............................................................... ≤0.075 °C at 30 °C target temp (75 mK)
Total pixels
Ti400 ............................................................... 76,800
Ti300 ............................................................... 43,200
Ti200 ............................................................... 30,000
Infrared spectral band ......................................... 7.5 μm to 14 μm (long wave)
Visual (Visible Light) Camera
Type .................................................................... Industrial performance 5.0 megapixel
Minimum parallax alignment
with standard IR lens .......................................... ~60 cm (~24 in)
Standard Infrared Lens
Field of View ....................................................... 24 x 17
Spatial Resolution (IFOV)
Ti400 ............................................................... 1.31 mRad
Ti300 ............................................................... 1.75 mRad
Ti200 ............................................................... 2.09 mRad
Minimum Focus Distance ................................... 15 cm (6 in)
Thermal Imagers
Detailed Specifications
25 C ambient
on model variation
45