Toshiba TECRA M10 Maintenance Manual page 65

Hide thumbs Also See for TECRA M10:
Table of Contents

Advertisement

2.3 Power Supply Troubleshooting
E3V output
Error code Meaning
60h
E3V voltage is over 3.96V.
61h
E3V voltage is under 2.81V when the computer is powered on.
62h
E3V voltage is under 2.81V when the computer is booting up.
64h
E3V voltage is under 2.81V when EV power is maintained.
1R8-E1V output
Error code Meaning
70h
1R8-E1V voltage is over 2.16V.
71h
1R8-E1V voltage is under 1.53V when the computer is powered on.
72h
1R8-E1V voltage is under 1.53V when the computer is booting up.
74h
1R8-E1V voltage is under 1.53V when BV power is maintained.
1R5-P1V output
Error code Meaning
80h
1R5-P1V voltage is over 1.80V.
81h
1R5-P1V voltage is under 1.28V when the computer is powered on.
82h
1R5-P1V voltage is under 1.28V when the computer is booting up.
PPV output
Error code Meaning
90h
PPV voltage is over 1.56V.
91h
PPV voltage is under 0.27V when the computer is powered on.
92h
PPV voltage is under 0.59V when the computer is booting up.
TECRA M10 Maintenance Manual (960-685)