Cabling Tables; Connecting Infiniband Cables; Cable Routing Procedure For The Isr 9024 Or Isr 9024 S/D - HP Cluster Platform Interconnects v2010 User Manual

Hp cluster platform infiniband interconnect installation and user's guide
Hide thumbs Also See for Cluster Platform Interconnects v2010:
Table of Contents

Advertisement

Caution:
Do not bend the InfiniBand cables too sharply. The minimum bend radius is 4" (10 cm).
Follow the cabling procedure to avoid creating airflow dams, particularly for the ISR 9024,
which employs passive cooling.
Consider the requirements and constraints of the installation location. For example, if cooling
air is supplied through floor vents, avoid covering the vents. Avoid air leaks into cable
conduits by using the appropriate seals or baffles.
Use appropriate gaskets and cable protection where cables pass through metal openings.
Do not allow sharp metal edges to abrade or cut the cable cladding.
Do not kink the cable.
Do not twist the connector.

7.1.2 Cabling Tables

The following documents provide cabling tables for supported InfiniBand configurations:
InfiniBand 1U Server 2:1 Reduced Bandwidth Cabling Tables
InfiniBand 1U Server Full Bandwidth Cabling Tables
InfiniBand 2U Server 2:1 Reduced Bandwidth Cabling Tables
InfiniBand 2U Server Full Bandwidth Cabling Tables
InfiniBand 4U Server 2:1 Reduced Bandwidth Cabling Tables
InfiniBand 4U Server Full Bandwidth Cabling Tables
You can find these documents on the following Web site:http://docs.hp.com, under the heading
High Performance Computing.

7.1.3 Connecting InfiniBand Cables

Use the following procedure to connect an InfiniBand cable:
1.
Align the InfiniBand cable connector with the port on a line board.
2.
Depending on the type of cable in use:
Squeeze the tabs on either side of the head shell (see callout 1 in
the connector onto the port, releasing the tabs to lock the head shell in place
Pull back the locking handle on the head shell (see callout 2 in
connector onto the port by holding the head shell body (not the handle). Push in the
handle to lock the head shell in place.
3.
Pull gently on the head shell (never on the cable) to ensure that the connector has locked in
place.
4.
Route the cable to the nearest cabling guide hook, in accordance with the cable routing
procedure for your model of Cluster Platform.
5.
Verify that the Link State green LED illuminates and does not flash. This indicates a good
physical connection. See

7.1.4 Cable Routing Procedure for the ISR 9024 or ISR 9024 S/D

Refer to the appropriate cabling tables for your model of HP Cluster Platform. The cabling tables
define the syntax of the port names for origin and destination ports. Every port has a unique
designator to ensure correct cabling.
86
Cabling the Interconnect