The following status values are associated with port failures:
BROKEN_LINK
One end of the physical link is up, but the other end is unreachable.
INVALID_LINK
The port shows different connectivity on both sides of the link.
DUPLICATE_HCA_GUID
Another HCA (or interconnect) exists with the same GUID.
DUPLICATE_SWITCH_GUID
Another interconnect exists with the same GUID.
Functioning ports are discovered automatically when the fabric is polled or initialized. If the
fabric management software detects a failed port, it sets the status of the remote port to Down.
It also records the port's failed status as Down/Polling in the internal fabric database. This
database entry indicates that the port is not connected. In future polls or initialization events,
the port is not discovered unless the problem is corrected and you clear the entry in the failed
port table. Use the following procedure to display and clear failed ports:
1.
To display the bad port table, select the following option from the device manager's main
menu:
Device
Bad Ports Log
A browser window is displayed, showing the bad ports.
2.
To clear the bad port table, launch the CLI as described in Voltaire InfiniBand Fabric
Management and Diagnostic Guide and use the enable command to enter privileged mode,
specifying the privileged mode password when prompted.
3.
Type the Config command to enter configuration mode, specifying the Config mode
password when prompted.
4.
Type the sm command to enter Subnet Manager configuration mode.
5.
Type the following command to clear all bad ports:
# bad-ports-clear set
9.5 Detecting a Failed Port