2.15.2

Basic setting with the control panel V810 or V820

2
Caution: Danger of injury !
Adjust the potentiometer only with the main switch switched off.
Work with utmost caution.
Loosen the stop screw 1 for the potentiometer 2.
Keep the key "P" pressed and switch on the main switch.
Enter the technician level.
Select the parameter "F-188".
Actuate the key "E".
The current Speedomat grade (e.g. 11) and the corresponding
driving speed limitation (e.g. 2860) are displayed.
Turn the potentiometer shaft until the Speedomat grade "07" and
the corresponding maximum driving speed of 3800 rpm resp. 3400
rpm (depending on the subclass) are indicated on the display.
Tighten the stop screw 1.
Check the setting.