Troubleshooting - Schwinn 520 Reclined Elliptical Assembly Manual

Reclined elliptical
Hide thumbs Also See for 520 Reclined Elliptical:
Table of Contents

Advertisement

TroublesHooTIng

Condition/Problem
No display/partial display/
unit will not turn on
Unit operates but Contact
HR not displayed
Console displays "Lbat"
error code
Speed displayed is not
accurate
Console displays "E2" er-
ror code
No speed/RPM reading
while pedaling, Console
displays "Please Stride"
error code
28
Things to Check
Batteries
Check data cable integrity
Check data cable
connections/orientation
Check console display for
damage
Console Display
HR cable connection at
Console Support Arm and
Handlebar
Sensor grip
Dry or calloused hands
Handlebar and Console
Support Arm
Batteries
Display set to wrong unit
of measure (English/Met-
ric)
Check data cable integrity
Check data cable
connections/orientation
Console Electronics
Check data cable integrity
Check data cable
connections/orientation
Check magnet position
(requires shroud removal)
Check Speed Sensor (re-
quires shroud removal)
Make sure batteries are installed correctly. If batteries are cor-
rectly installed, replace with a set of new batteries.
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check for visual sign that console display is cracked or other-
wise damaged. Replace Console if damaged.
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact Cus-
tomer Care for further assistance.
Be sure cables are connected securely.
Be sure hands are centered on HR sensors. Hands must be
kept still with relatively equal pressure applied to each side.
Sensors may have difficulty with dried out or calloused hands.
A conductive electrode cream such as "Signa Crème" or "Buh-
Bump" can help make better conduct. These are available on
the web or at medical or some larger fitness stores.
If tests reveal no other issues, Handlebar and Console Support
Arm should be replaced.
Replace batteries
Console displays units.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
If tests reveal no other issues, Console should be replaced.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Magnet should be in place on pulley.
Speed sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Solution

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents