EN | 56
Gateway IP address:
If you want the unit to establish a connection to a remote location in a different
subnet, enter the IP address of the gateway here. Otherwise leave the box blank
(0.0.0.0).
Ethernet link type:
If the unit is connected to the network via a switch, both must have the same
default for the type of network connection. If necessary, ask your network admin-
istrator what value the switch is set to.
The Auto setting automatically detects the network connection. If necessary,
you can specify the value 10 or 100 MBit/s for full or half-duplex mode (FD or
HD) or 1 GBit/s FD.
Caution
Malfunctions such as image faults can occur if the network does not have
enough capacity to transmit the maximum data rate generated by the unit.
Dynamic DNS server IP address:
When operating a unit on the Internet, dynamic addresses are used to ensure
efficient use of the available IP address pool. That is, the unit is reassigned a
(changing) IP address each time a new connection is made. Access is easier if
the unit is listed in a DNS server. It registers there at regular intervals and leaves
the unit name and its IP address. If you wish to establish an Internet connection
to a unit, it is sufficient to enter the appropriate unit name together with the URL
of the DNS server. This then reports on the current Internet IP address used to
establish the connection.
Dynamic DNS contact interval:
Enter the desired refresh interval in seconds here.
Configuration using a Web browser
Installation and Operating Manual | VideoJet 8008 / VideoJet 8004
Bosch Security Systems | 2006-07 | V1.5