Zoneline Chassis Nomenclature/Receptacles/Sub-Bases - GE ZONELINE 2800 Data Manual

Zoneline packaged terminal air conditioners 2800 series; 3800 series; 5800 series
Table of Contents

Advertisement

Zoneline
Chassis Nomenclature
®
The Zoneline chassis is identified by a model number defining
the type of unit, cooling capacity, electrical information and
optional features included on the unit. When specifying or
ordering the Zoneline chassis use of this nomenclature will
assure receiving the correct unit.
Receptacles/Sub-Bases
Premium Line: 5800 Series
Tandem
Perpendicular
20/208V 15 Amp
20/208V 20 Amp
NEMA6-15R
NEMA6-20R
Sub-Bases
RAK204U
Voltage
N/A
Amps
N/A
Receptacle
N/A
20/208-Volt sub-bases include appropriate power cord kit.
265-Volt units are to be direct connected. Cordset through enclosed chaseway into interior sub-base receptacle meets the NEC requirements.
Power connection kits are required on all
Zoneline chassis (see chart below).
The correct kit for the installation is determined by the voltage and
amperage of the electrical circuit and the means of connecting the
unit to the building wiring. If the unit is to be plugged into a receptacle,
a line cord kit would be used; if the unit is to be permanently connected,
a permanent connection kit would be used. 265-volt cord set units must
be installed in compliance with National Electrical Code.
20/208-volt
LCDI Power Connection Kit
RAK15
Heater KW
2.55/2.09
Watts
2,550/2,090
BTUH
8,600/7,100
Amps
11.0/10.0
Min. circuit amps
Recommended
15-amp
protective
time-delay
device
fuse or breaker
*To be used with sub-base
54
Large tandem
20/208V 0 Amp
NEMA6-0R
RAK204D15P
RAK204D20P
20/208
15
NEMA6-20R
Line cord connected units
RAK20
RAK0
.45/2.82
,450/2,820
5,000/4,090
11,700/9,600
17,000/1,900
15.0/1.6
15
20
20-amp
time-delay
time-delay
fuse or breaker
fuse or breaker
EXAMPLE
A
Z
5
Zoneline
Chassis series
28= deluxe line cool/
packaged
electric heat
terminal
8=deluxe line heat pump
chassis
58= premium line
heat pump
Unit type
E= cooling with electric
resistance heat
H= heat pump with electric
resistance heat
265V 15 Amp
NEMA7-15R
RAK204D0P
20/208
20/208
20
0
NEMA6-20R
NEMA6-0R
RAK15 and RAK20
20/208-volt line cord
connection kit
265-volt Permanent connected units* (Cord set)
RAK5172
2.55
5.00/4.09
2,560
8,600
9.6
21.7/19.7
15
0
15-amp
0-amp
time-delay fuse
8
H
1
2
Nominal cooling capacity
07=7,000 BTUH cooling
09=9,000 BTUH cooling
12=12,000 BTUH cooling
15=15,000 BTUH cooling
Voltage/Phase/
Frequency
D= 20/208 Volt, single
phase, 60 Hz
E= 265 Volt, single phase,
60 Hz
265V 20 Amp
265V 0 Amp
NEMA7-20R
NEMA7-0R
RAK204E15
RAK204E20
265
265
15
20
NEMA7-15R
NEMA7-20R
Power connection kits
required on all models.
See specification sheet
for heater KW and
branch circuit ampacity.
RAK0
20/208-volt line cord
connection kit
RAK5202
RAK502
.45
5.0
,450
5,000
11,700
17,000
1.0
18.9
20
0
20-amp
0-amp
time-delay fuse
time-delay fuse
D
A
D
Universal
power connection
Special Features
B=base unit
C=corrosion treated
D= internal
condensate
removal (ICR)
system (heat
pump models
only) (not for
coastal areas)
P=Dry Air 25
RAK204E0
265
0
NEMA7-0R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents