GE ZONELINE 2800 Data Manual page 8

Zoneline packaged terminal air conditioners 2800 series; 3800 series; 5800 series
Table of Contents

Advertisement

Zoneline
Features
®
Enhanced Dehumidification — Dry Air 25
Cooling EER Range (20 Volts/265 Volts)
Heating COP Range (20 Volts/265 Volts)
Heat Source — Electric Resistance Heat
Heat Source — Heat Pump With Selectable
Full Time or On Demand Simultaneous/
Supplemental Resistance Heat
Staged Heating
Universal Heater — UPC*
Unit Controls
Electronic Temperature Selection
(Slews Up & Down) with Digital Display
Unit Diagnostics
Highly Featured Microprocessor Controls
Electric Resistance Heat Lock-Out (above 46°F)
Automatic Emergency Heat
Heat Pump Defrost System
High Temperature Operation Protection
Quick Heat Recovery
Temperature Boost
Service Indicator
Fan Motors — Permanently Lubricated
2-Speed Outdoor Fan
Indoor Fan Speed Selections — HIGH/LOW
Fan Only Setting — HIGH/LOW
Fan Cycle Switch
Constant-Run Fan
Rotary Compressor
Automatic Compressor Restart Delay
Freeze Sentinel
Heat Sentinel
Indoor Coil Frost Control
Transfer Fan Connections
7-Step Electronic Temperature Limiting
Remote Control Capability with Wall Mounted Thermostat
Central Desk Control Capability
Energy Management System Interface with Load Shedding Option
Reversible Indoor Air Louvers 40º/50º
Up-Front Filters
Easy-Clean Air Discharge Area
Concealed Manual Vent Control
Ducted Installation Capability
Corrosion Protection (Standard on Dry Air 25)
Internal Condensate Removal (ICR) (Factory Installed Option.
Cannot be used in Corrosion Areas.)
*UPC — Universal Power Cord Connection (See pages 42 and 55).
265-volt units must be connected in a manner to meet National Electrical Code and all local codes.
8
AZ
AZ
2800
800
Optional
N/A
10.2 - 12.7
10.0 - 12.7
N/A
.2 - .6
Standard
Standard
 Stage
Standard
Standard
Rotary Knobs
Rotary Knobs
Standard
Standard
Standard
Standard
Reverse Cycle
Standard
Standard
Selectable
2
2
Standard
Standard
Standard
Standard
Standard
Standard
"Smart Fan"
"Smart Fan"
Selectable
Selectable
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
RAK6052
RAK6052
Optional
Optional
N/A
Optional
AZ
5800
N/A
10.2 - 1.0
.2 - .6
Standard
 Stage
Standard
Touch Pad
Standard
Standard
Standard-Plus
Standard
Standard
Reverse Cycle
Standard
Standard
Selectable
Temp Display Blinks
2
Standard
HIGH/LOW/AUTO
Standard
"Smart Fan"
Selectable
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Optional