Auxiliary Control Switches

These switches are located behind the room cabinet under the control panel.
2800 and 800 Series
Switches
Description
Left Switches
(1)
ALL I2R
(2)
C: FAN
()
H: FAN
(4)
CLASS 2
(5)
LOAD SHED
(6)
FREEZ S
(7)
CONST FAN
(8)
OCCUPIED
Right Switches
TL1 – TL
TL4 – TL6
(7)
(8)
800 Series shown
UP
DOWN
1
ALLI
R (All Electric Heat)
2
(3800 Series models only)
C: FAN CN (Cooling–Smart Fan)
H: FAN CY (Heating–Smart Fan)
CLASS 2 (Remote Thermostat)
LOAD SHEDDING (CDC)
FREEZ Sen (Freeze Sentinel)
CONST FAN (Constant ON Fan)
OCCUPIED (Occupancy Sensor)
Cooling and Heating temperature limits are set independently, temperature limiting
switches are in factory-set down position, except as noted.
Cooling Temperature Limits
Switches Up
NONE
60
64
Heating Temperature Limits
Switches Up
6
4, 6
65
70
12
Heat pump override —
Down — Normal heat pump operation
Up — resistance heat only (800 Series only)
Fan control for cooling operation —
Down — Fan Continuous
Up — Fan Cycle
Fan control for heating operation —
Down — Fan Cycle
Up — Fan Continuous
Remote Thermostat Mode —
Down — Unit Control
Up — Remote Thermostat
Load Shedding when connected to Central Desk Control System —
Down — Fan shuts off with unit
Up — Fan under "Smart Fan" settings
Freeze Sentinel
Override —
Down — Freeze Sentinel ON
Up — Freeze Sentinel OFF
Constant Fan —
Down — Fan runs normally
Up — Fan runs when unit is in STOP position
Occupancy Sensor Mode —
Down – Unit Control
Up — Occupancy Sensor Connected
Cooling temperature limiting (See table at bottom of page)
Heating temperature limiting (See table at bottom of page)
Heat Sentinel switch —
Down — Heat Sentinel OFF
Up — Heat Sentinel ON
Heat Boost (800 series only) —
Down — Heat Boost OF
Up — Heat Boost ON
Auxiliary (2800 and 800 series)
2
3
4
5
6
7
8
1
2
3
1
1, 2
2
66
68
4, 5, 6
5, 6
72
74
HIGH
UP
DOWN
COOL
4
5
6
7
8
HEAT BOOST
(3800 Series models only)
Heat Sentinel
TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)
TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)
2, 
1, 2, 
1, 
70
72
74
5
4, 5
4
76
78
80

76
NONE
85