MAINTENANCE AND TROUBLESHOOTING

Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power adapter is fully plugged in.
If the console displays become dim when batteries
are installed in the console, replace all the batteries at
the same time; most console problems are the result
of low batteries. See assembly step 14 on page 13 for
replacement instructions.
If the handgrip heart rate monitor does not function
properly, see step 5 on page 19.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. First, remove all of
the screws from both shields; there are three sizes
of screws in the shields—note which size of screw
you remove from each hole. Then, gently pry the
shields away from the frame.
Next, locate the
Reed Switch
(58). Turn the
Left Pedal Disc
(26) until a
Magnet (41) is
aligned with the
Reed Switch.
Loosen, but do
not remove, the
indicated M4 x
16mm Round
Head Screw (84).
Slide the Reed Switch slightly closer to or away from
the Magnet, and then retighten the Screw. Rock the
Left Pedal Disc forward and backward just enough that
the Magnet passes the Reed Switch repeatedly.
Repeat these actions until the console displays correct
feedback. When the reed switch is correctly adjusted,
reattach the shields. Note: If you have questions as to
which screw should be in which hole, see
EXPLODED DRAWING B on page 31 and the PART
LIST on page 28.
24
41
58
26
84