Configuring the GWS 10 if the Filter and Offset Selections Are Not Shown
Refer to your Garmin Chartplotter or marine instrument owner's manual for instructions regarding configuring NMEA 2000 devices.
To configure the orientation:
1. Select Generic Configuration to specify data for the filter and offset settings.
2. Enter the following command: "ANGLEOFFSET="
3. Follow the command with a number between 0 and 359, in degrees (for example: ANGLEOFFSET=180).
To configure the wind angle filter:
1. Select Generic Configuration to specify data for the filter and offset settings.
2. Enter the following command: "ANGLEFILTER="
3. Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the
automatic setting (for example: ANGLEFILTER=12).
To configure the wind speed filter:
1. Select Generic Configuration to specify data for the filter and offset settings.
2. Enter the following command: "SPEEDFILTER="
3. Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the
Automatic setting (for example: SPEEDFILTER=215).

NMEA 2000 PGN Information

Use the tables to determine the approved NMEA 2000 PGN information that can be received and transmitted by a GWS 10 when
communicating with a NMEA 2000-compliant device.
Transmit
059392
060928
126208
126464
126996
130306
130312
130314
Specifications
Physical
NOTE: The width of this sensor varies with the positioning of the
wind vane.
unit Dimensions: W × H × D: 19
(500–575 × 280 × 140 mm)
Weight: 0.6 lb. (0.275 kg)
Cable: Attached NMEA 2000 cable length is 18 in. (46 cm)
Temperature Range: From 5°F to 158°F (from -15°C to 70°C)
GWS 10 Installation Instructions
ISO Acknowledgment
ISO Address Claim
NMEA - Command/Request/
Acknowledge Group Function
Transmit/Receive PGN List Group
Function
Product Information
Wind Data
Temperature
Actual Pressure
/
–22
/
× 11
/
× 5
/
in.
11
5
1
1
16
8
32
2
Receive
059392
ISO Acknowledgment
059904
ISO Request
060928
ISO Address Claim
126208
NMEA - Command/Request/
Acknowledge Group Function
The GWS 10 is NMEA 2000
certified
Case Material:
Housing and Base: PC/ABS
Wind vane and Anemometer: Polypropylene
Tubing: 6063 Aluminum
Shafts: 304 SS
Power
power input Source: 9–16 Vdc via NMEA 2000
NMEa 2000 Load Equivalency Number (LEN): 2 (100 mA)