A Monthly:
,
Door springs and door hardware.:
-
Oil door roller,bearings,and hingesusing silicone
lubricant or light oil.
DortotoperatedooraUtomatically or manually ifspringsI
are broken. Contacta GenieFactoryAuthorizedDealerfor
service or Call C ustomerServiceat IoBO0o35oGENJE.
J
,
BaBnceDoor.
-
Closedoor.
-
Release Magnetb CarriageAssemblyfrom RailAssembly
by pulling down on EmergencyRelease Knob.
-
Raisedoor manually 3'- 4' and verify that door staysat
that position.SeeCheckStep2 on page 4.
When the door is 3'- 4' abovethe ground, the door
should stay open. Slight movement isacceptable, if
the door moves too much,contact a Genie Factory
Authorized Dealerfor service or call CustomerService
1-800-35-GENIE.
at
-
ReattachMagneticCarriageAssembly t o RailAssemblyby
pulling the Emergency Release Knobtoward PowerHead.
-
Closedoor.
Contact Reverse Test.
-
Perform Adjustment 2 on page 8.
! WARNING
If the door fails to reverseon contact with the board
adjust the CloseForceControlasspecified in Set Jmit
Switchesand ForceControtson #age 7. If the Openerstill
fails,contact a GenieFactoryAuthorized Dealerfor service
or callCustomerServiceat loBO0.35.GENJE.
B Yearly:
Wipe off old excesslubricant from Drive Screw
Lubricate Drive Screwwith Genie Lubricant GLU-3t
UseONLYGenie Lubricant (GLU-3). Other lubricants
may damagethe Opener.
GLU-3
lubricant
FCC AND (C CERT(F(ED
ing interferencethat may causeundesired operation.
TROUBLESHOOTING
GUIDE
Safe=T=Beam® System Self=Diagnostic
Troubleshooting
Source (Red LED)
Sensor (Green LED)
Possible Problem
Solution
ON
ON
Normal operation
o Power Head not powered
• Check breakers, fuses, plugs
OFF
OFF
o Wiring from Power Head bad
o Check wiring for obvious shorts
OFF
ON
. Wiring to Source missing or bad
. Check wiring
o Power has been interrupted
o Remove power and reapply
2 BLINKS, Pause
o Beam not aligned
o Check Source, Sensor alignment
(Repeat)
ON
• Beam obstructed
• Check for obstruction
• Sensor defective
o Contact Customer Service
2 BLINKS, Pause
• Wire to Sensor missing or bad
• Check wiring
(Repeat)
OFF
• Sensor defective
• Contact Customer Service
s BLINKS, Pause
• Sensor receiving interference
• Determine source of interference
(Repeat)
ON
• Contact Customer Service
4 BLINKS, Pause
• Source not sending pubes
• Contact Customer Service
(Repeat)
ON
o Source defective
o Contact Customer Service
10
For Help, call 1-800-35-GENmE or visit www.geniecompany.com