Electrical Data; Weighted Sound Level; Weighted Sound Level (Dba) With Sound Hood; Charging Subcooling - Carrier 25HBR3 Product Data

Base series 13 heat pump sizes 18 to 60 1-1/2 to 5 nominal tons
Table of Contents

Advertisement

ELECTRICAL DATA

UNIT SIZE ---
V/PH
VOLTAGE,
SERIES
18---30
24---30
30---30
36---30
208/230/1
42---30
48---30
60---30
30---50
36---50
42---50
208/230/3
48---50
60---50
36---60
42---60
460/3
48---60
60---60
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30° C (86° F), consult table 310 ---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed cable
(NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60
or 75° C (140 or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables
of the NEC (ANSI/NFPA 70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time ---Delay fuse.
FLA
--- Full Load Amps
LRA
--- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA
--- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All
motors/compressors contain internal overload protection.
A- -WEIGHTED SOUND LEVEL (dBA)
UNIT SIZE --- VOLTAGE, SERIES
18---30
24---30
30---30, 50
36---30, 50, 60
42---30, 50, 60
48---30, 50, 60
60---30, 50, 60
A- -WEIGHTED SOUND LEVEL (dBA) WITH SOUND HOOD
UNIT SIZE --- VOLTAGE, SERIES
18---30
24---30
30---30, 50
36---30, 50, 60
42---30, 50, 60
48---30, 50, 60
60---30, 50, 60
CHARGING SUBCOOLING (TXV- -TYPE EXPANSION DEVICE)
UNIT SIZE --- VOLTAGE, SERIES
OPER VOLTS*
COMPR
MAX
MIN
LRA
RLA
41
9.0
54
11.3
72.5
14.8
253
187
88
17.0
104
21.2
137
21.2
148
28.9
63
10.4
77
11.3
253
197
88
13.4
91
13.78
123
18.7
39
5.5
44
6.4
506
414
46
7.1
62
8.6
STANDARD
RATING
75
76
76
76
76
76
77
STANDARD
RATING
74
75
75
75
76
75
75
18---30
24---30
30---30, 50
36---30, 50, 60
42---30, 50, 60
48---30, 50, 60
60---30, 50, 60
MIN
FAN
WIRE
MCA
SIZE
{
FLA
60° C
0.5
11.70
14
0.8
14.80
14
0.8
19.20
12
0.9
22.10
12
0.9
27.40
10
1.2
27.60
10
1.2
37.30
8
0.75
13.75
14
0.9
15.03
12
0.9
17.65
12
1.2
18.43
10
1.2
24.58
8
0.5
7.38
14
0.5
8.50
14
0.6
9.41
14
0.6
11.35
14
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125
250
500
52
59.5
64.5
52.5
63.5
69.5
52
64
70
53
69
66.5
57
65
68
57.5
65
68
61
62.5
70
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125
250
500
52.0
59.5
64.0
53.5
63.0
69.0
53.0
64.5
69.5
54.0
68.5
65.5
58.0
64.5
67.0
58.0
64.0
68.0
59.5
61.5
67.5
REQUIRED SUBCOOLING (_F)
7
MIN
MAX
MAX
WIRE
LENGTH
LENGTH
SIZE
(FT)
(FT)
{
}
}
75° C
60° C
75° C
14
166
158
14
131
125
12
161
154
12
140
133
10
181
172
10
179
170
8
207
197
14
66
63
12
96
92
12
82
78
10
125
119
10
146
89
14
247
235
14
214
203
14
193
184
14
160
152
1000
2000
4000
71
67
61.5
72
67.5
64.5
71
68
66.5
69.5
66.5
63.5
72.5
67.5
64
70.5
69
64
72.5
70
67
1000
2000
4000
68.0
64.0
60.0
70.5
66.5
64.0
70.5
67.5
64.5
68.0
65.0
62.0
71.0
65.5
61.0
69.0
65.5
60.5
70.0
68.0
64.0
11
11
9
11
13
13
11
MAX
FUSE**
or CKT
BRK
AMPS
20
25
30
35
40
40
60
20
25
25
30
35
15
15
15
15
8000
54.5
59.5
65
62
59
60.5
60
8000
52.5
58.5
60.5
57.5
54.5
55.5
57.5