Carrier 25HCB5 Product Data

Comfortt 15 series heat pump with puron refrigerant 1-1/2 to 5 nominal tons (sizes 18 to 60)
Hide thumbs Also See for 25HCB5:

Advertisement

Quick Links

25HCB5
Comfortt 15 Series Heat Pump
with Puronr Refrigerant
1---1/2 To 5 Nominal Tons (Sizes 18 To 60)
the environmentally sound refrigerant
Carrier's heat pumps with Puronr refrigerant provide a collection
of features unmatched by any other family of equipment. The
25HCB5 has been designed utilizing Carrier's Puron refrigerant.
The environmentally sound refrigerant allows consumers to make
a responsible decision in the protection of the earth's ozone layer.
As an Energy Starr Partner, Carrier Corporation has determined
that this product meets the Energy Starr guidelines for energy
efficiency. Refer to the combination ratings in the Product Data
for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
Sound
Comfort
Reliability
Durability
WeatherArmort protection package:
Applications
S
Long- -line - - up to 250 feet (76.20 m) total equivalent length,
up to 200 feet (60.96 m) condenser above evaporator, or up to
80 ft. (24.38 m) evaporator above condenser (See Longline
Guide for more information.)
S
Low ambient (down to - -20_F/- -28.9_C) with accessory kit
S
15 SEER/ 11.2 - - 13.0 EER/ 7.7 - - 8.8 HSPF (Nominal)
S
Microtube Technologyt refrigeration system
S
Indoor air quality accessories available
S
Sound level as low as 70 dBA
System supports Thermidistatt or standard thermostat
S
controls
S
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime service cost.
S
Front- -seating service valves
S
Scroll compressor
S
Internal pressure relief valve
S
Internal thermal overload
S
High pressure switch
S
Loss of charge switch
S
Filter drier
S
Balanced refrigeration system for maximum reliability
S
Solid, durable sheet metal construction
S
Steel louver coil guard
S
Baked- -on, complete coverage, powder paint

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 25HCB5

  • Page 1: Product Data

    Loss of charge switch Filter drier Balanced refrigeration system for maximum reliability Carrier’s heat pumps with Puronr refrigerant provide a collection Durability of features unmatched by any other family of equipment. The 25HCB5 has been designed utilizing Carrier’s Puron refrigerant.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Product Major Cooling Minor Tier SEER Variations Open Open Voltage Series Family Series Capacity Series 3=208/230 ---1 0=Not 0=Not 5=208/230 ---3 25 = HP H = RES HP C=Comfort B = Puron 5=15 SEER A = Standard 0, 1, 2...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE SERIES Operating Weight lb (kg) (79.0) (99.3) (112.0) (115.2) (127.0) (134.0) (155.1) Shipping Weight lb (kg) (91.2) (119.3) (128.4) (132.0) (143.3) (154.7) (173.3) Compressor Type Scroll REFRIGERANT Puron (R---410A) Control TXV (Puron Hard Shutoff) Charge lb (kg) 6.4 (2.9) 7.3 (3.3) 11.2 (5.1)
  • Page 4: Accessory Thermostats

    * Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non ---programmable air conditioner version and builder;s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
  • Page 5: Accessory Usage Guideline

    ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW --- AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS LONG LINE APPLICATIONS* SEA COAST APPLICATIONS (Below 55°F / 12.8°C) (Over 80 ft. / 24.38 m) (Within 2 miles / 3.22 km) Accumulator Standard Standard Standard Ball Bearing Fan Motor Yes{...
  • Page 6 Accessory Description and Usage (Listed Alphabetically) - - CONTINUED 10. Outdoor Air Temperature Sensor 14. Sound Hood Designed for use with Carrier Thermostats listed in this Wraparound sound reducing cover for the compressor. Reduces publication. This device enables the thermostat to display the the sound level by about 2 dBA.
  • Page 7: Electrical Data

    ELECTRICAL DATA FUSE** OPER VOLTS* COMPR WIRE WIRE LENGTH LENGTH UNIT or CKT V/PH SIZE{ SIZE{ ft (m)†† ft (m)†† SIZE 60° C 75° C 60° C 75° C AMPS 18--- 30 48.0 11.9 66 (20.1) 62 (18.9) 24--- 30 58.3 12.8 16.5...
  • Page 11 Wall...
  • Page 12: Combination Ratings

    COMBINATION RATINGS High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3032195 25HCB518A30 †FX4CNF018 17400 11.7 14.50 17700 3.56 10300 2.32 3032220 25HCB518A30 FE4ANF002+UI 17600 12.0 15.00 17500...
  • Page 13: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3106277 25HCB524A30 CNPH*2417A** 58MEB060---12 23200 12.5 15.00 24000 3.86 14600 2.66 3106278 25HCB524A30 CNPH*2417A** 58MEB080---12 23200...
  • Page 14 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3032400 25HCB530A30 FE4AN(B,F)005+UI 30000 13.0 16.50 29400 17300 2.64 3032398 25HCB530A30 FE4ANF002+UI 29000 13.0 15.75 29200...
  • Page 15 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3106299 25HCB530A30 CNPV*3017A** 58MEB080---16 29200 13.0 15.50 29600 3.72 17500 2.54 3032336 25HCB530A30 CNPV*3017A** 58MV(B,C)060---14 28600...
  • Page 16 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3032457 25HCB536A30 CAP**3621A** 58CV(A,X)110---20 34400 12.7 15.25 35000 3.62 20800 2.54 3106328 25HCB536A30 CAP**3621A** 58MEB100---20 34600...
  • Page 17 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3032471 25HCB536A30 CNPV*3621A**+TDR 34400 11.2 13.50 36000 3.54 22000 2.46 3106322 25HCB536A30 CNPV*4217A** 58CV(A,X)090---16 34800 12.5...
  • Page 18 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3032580 25HCB542A30 CAP**4224A** 58CV(A,X)155---22 41500 12.5 15.00 41500 3.58 25200 2.60 3106365 25HCB542A30 CAP**4224A** 58MEB120---20 42000...
  • Page 19 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3106361 25HCB542A30 CNPV*4217A** 58MV(B,C)060---14 42000 12.0 14.50 42000 3.62 26000 2.58 3106363 25HCB542A30 CNPV*4217A** 58PH*070---16 41500...
  • Page 20 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3032732 25HCB548A30 FY4ANB060 48000 11.5 14.00 47000 30000 2.50 3032731 25HCB548A30 FY4ANF048 47000 11.2 13.50 46500...
  • Page 21 COMBINATION RATINGS CONTINUED High Temp Low Temp ARI Ref. Model Furnace Cooling Coil Model Number SEER HSPF Number Model Number Capacity E COP H COP Capacity Capacity 3032719 25HCB548A30 CSPH*4812A** 58CV(A,X)090---16 46500 12.0 14.50 45000 3.54 28800 2.50 3032720 25HCB548A30 CSPH*4812A** 58CV(A,X)110---20 46500...
  • Page 44: Guide Specifications General

    Catalog No. 25HCB5---3PD Copy right 2009 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date:02/09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents