Carrier 25HBR3 Product Data
Carrier 25HBR3 Product Data

Carrier 25HBR3 Product Data

Base series 13 heat pump sizes 18 to 60 1-1/2 to 5 nominal tons

Advertisement

25HBR3
BasetSeries 13 Heat Pump
Sizes 18 To 60
1---1/2 to 5 Nominal Tons
Shown with optional dense coil guard

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
S
S
Sound
S
Comfort
S
Reliability
S
S
S
S
S
Durability
WeatherArmort protection package:
S
S
S
Applications
S
S
Warranty
Single Phase
S
S
Three Phase
S
S
13 SEER/ 11 EER / Up to 8.6 HSPF (Nominal)
Microtube Technologyt refrigeration system
Indoor air quality accessories available
Sound level as low as 75 dBA
System supports Thermidistatt or standard thermostat
controls
Front- -seating service valves
Scroll compressor
Filter drier
Loss of charge pressure switch
Balanced refrigeration system for maximum reliability
Solid, Durable sheet metal construction
Wire coil guard
Baked- -on, complete coverage, powder paint
Long- -line - - up to 250 feet total equivalent length, up
to 200 feet condenser above evaporator, or up to 80 ft.
evaporator above condenser (See Longline Guide for
more information.)
Low ambient (down to - -20_F) with accessory kit
5 year limited compressor warranty
5 year limited parts warranty
5 year limited compressor warranty
1 year limited parts warranty

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 25HBR3

  • Page 1: Product Data

    25HBR3 BasetSeries 13 Heat Pump Sizes 18 To 60 1---1/2 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency 13 SEER/ 11 EER / Up to 8.6 HSPF (Nominal) Microtube Technologyt refrigeration system Indoor air quality accessories available...
  • Page 2: Model Number Nomenclature

    Original Coil Guard 6=460/3 Series ISO 9001:2000 REGISTERED As an Energy Star® Partner, Carrier Corporation has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines.
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE SERIES 18---30 24---30 30---30, 50 36---30, 50, 42---30, 50, 48---30, 50, 60---30, 50, 60 Operating Weight (lb) Shipping Weight (lb) Compressor Type Scroll REFRIGERANT Freon® (R--- 22) Control TXV (R--- 22 Hard Shutoff) Charge (lb) 15.5 COND FAN Propeller Type, Direct Drive Air Discharge...
  • Page 4 * Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non ---programmable air conditioner version and builder;s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
  • Page 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW---AMBI- REQUIRED FOR LONG REQUIRED FOR SEA Accessory ENT APPLICATIONS LINE APPLICATIONS* COAST APPLICATIONS (Below 55° F) (Over 80 Ft.) (Within 2 miles) Crankcase Heater Evaporator Freeze Thermostat Accumulator Compressor Start Assist Capacitor and Relay Motor Master ®...
  • Page 6 Accessory Description and Usage (Listed Alphabetically) - - CONTINUED 11. Outdoor Air Temperature Sensor 15. Thermostatic Expansion Valve (TXV) Bi- -Flow Designed for use with Carrier Thermostats listed in this A modulating flow- -control valve which meters refrigerant liquid publication. This device enables the thermostat to display the flow rate into the evaporator in response to the superheat of the outdoor temperature.
  • Page 7: Electrical Data

    ELECTRICAL DATA FUSE** OPER VOLTS* COMPR WIRE WIRE LENGTH LENGTH UNIT SIZE --- V/PH or CKT VOLTAGE, SIZE SIZE (FT) (FT) SERIES 60° C 75° C 60° C 75° C AMPS 18---30 11.70 24---30 11.3 14.80 30---30 72.5 14.8 19.20 36---30 208/230/1 17.0...
  • Page 9 MBTUH CAPACITY, HEATING INTEGRATED UNIT LOSS, HEAT BUILDING...
  • Page 10 COMBINATION RATINGS ARI Standard Ratings Cooling Heating Unit Size Cooling --- voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Series HSPF Enhance Rating E COP Capacity H COP Capacity *FA4CN(F,C)018 17,100 TDR&TXV 13.00 10.80 18,000 3.52 10,500 2.34...
  • Page 11 COMBINATION RATINGS - - CONTINUED ARI Standard Ratings Cooling Heating Unit Size Cooling --- voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Series HSPF Enhance Rating E COP Capacity H COP Capacity CNRV*2414A** 22,800 13.00 10.80 23,800 3.66...
  • Page 12 COMBINATION RATINGS - - CONTINUED ARI Standard Ratings Cooling Heating Unit Size --- Cooling voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Serie HSPF Enhance Rating Capacity E COP Capacity H COP *FA4CN(F,C)030 28,400 TDR&TXV 13.00 10.80 30,200...
  • Page 13 COMBINATION RATINGS - - CONTINUED ARI Standard Ratings Cooling Heating Unit Size --- Cooling voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Serie HSPF Enhance Rating Capacity E COP Capacity H COP CNRH*3617A** 28,400 TDR&TXV 14.00 11.50 29,000...
  • Page 14 COMBINATION RATINGS - - CONTINUED ARI Standard Ratings Cooling Heating Unit Size --- Cooling voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Serie HSPF Enhance Rating Capacity E COP Capacity H COP CNRV*4221A** 33,600 TDR&TXV 13.20 11.00 35,200...
  • Page 15 COMBINATION RATINGS - - CONTINUED ARI Standard Ratings Cooling Heating Unit Size --- Cooling voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Serie HSPF Enhance Rating Capacity E COP Capacity H COP CAR**4224A** 40,500 TDR&TXV 13.20 11.00 41,000...
  • Page 16 COMBINATION RATINGS - - CONTINUED ARI Standard Ratings Cooling Heating Unit Size --- Cooling voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Serie HSPF Enhance Rating Capacity E COP Capacity H COP CSRH*4212A** 41,000 TDR&TXV 13.50 11.20 41,000...
  • Page 17 COMBINATION RATINGS - - CONTINUED ARI Standard Ratings Cooling Heating Unit Size --- Cooling voltage, Indoor Model High Temp Low Temp Capacity Factory Standard SEER Furnace Model Serie HSPF Enhance Rating Capacity E COP Capacity H COP CNRH*6024A** 45,500 TDR&TXV 13.20 11.00 47,500...
  • Page 18 DETAILED COOLING CAPACITIES CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Total Total Total Total Total Total Capacity Capacity Capacity Capacity Capacity Capacity Sys- Sys- Sys- Sys- Sys- Sys- MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡...
  • Page 19 DETAILED COOLING CAPACITIES - - CONTINUED CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System Sens Sens Sens Sens Sens Sens...
  • Page 20 DETAILED COOLING CAPACITIES - - CONTINUED CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Total Total Total Total Total Total Capacity Capacity Capacity Capacity Capacity Capacity Sys- Sys- Sys- Sys- Sys- Sys- MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡...
  • Page 21 DETAILED COOLING CAPACITIES - - CONTINUED CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Total Total Total Total Total Total Capacity Capacity Capacity Capacity Capacity Capacity Sys- Sys- Sys- Sys- Sys- Sys- MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Total Sens‡ Total Sens‡...
  • Page 22 DETAILED COOLING CAPACITIES - - CONTINUED CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System Sens Sens Sens Sens Sens Sens...
  • Page 23 DETAILED COOLING CAPACITIES - - CONTINUED CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR AIR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† System MBtuh† System MBtuh† System MBtuh† System MBtuh† System MBtuh† System KW** KW** KW** KW** KW**...
  • Page 24 DETAILED COOLING CAPACITIES - - CONTINUED CONDENSER ENTERING AIR TEMPERATURES deg F EVAPORATOR Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† System System System System System System Sens Sens Sens Sens Sens Sens...
  • Page 25 HEAT PUMP HEATING PERFORMANCE OUTDOOR COIL ENTERING AIR TEMPERATURES deg F INDOOR AIR --- 3 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys-...
  • Page 26 HEAT PUMP HEATING PERFORMANCE - - CONTINUED OUTDOOR COIL ENTERING AIR TEMPERATURES deg F INDOOR AIR --- 3 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh...
  • Page 27 HEAT PUMP HEATING PERFORMANCE - - CONTINUED OUTDOOR COIL ENTERING AIR TEMPERATURES deg F INDOOR AIR --- 3 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh...
  • Page 28 HEAT PUMP HEATING PERFORMANCE - - CONTINUED OUTDOOR COIL ENTERING AIR TEMPERATURES deg F INDOOR AIR --- 3 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh...
  • Page 29 HEAT PUMP HEATING PERFORMANCE - - CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES deg F --- 3 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh...
  • Page 30 HEAT PUMP HEATING PERFORMANCE - - CONTINUED OUTDOOR COIL ENTERING AIR TEMPERATURES deg F INDOOR AIR --- 3 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh...
  • Page 31 HEAT PUMP HEATING PERFORMANCE - - CONTINUED OUTDOOR COIL ENTERING AIR TEMPERATURES deg F INDOOR AIR --- 3 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh Sys- MBtuh...
  • Page 32 Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Copyright 2006 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. edition date: 03/06 Catalog No: 25HBR3---3PD Replaces:25HBR3---2PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents