Important:
• When using Pelco protocol, make sure that the system works properly before use. Some functions using Pelco
protocol may be restricted when this camera and the apparatuses (commercially available) compatible with
Pelco protocol operate together.
Note:
• When using the Unit Number 1 to 96 of Panasonic Protocol and using the Unit Number 32 to 96 of Pelco-D
protocol, the unit number setting needs to be configured using the RS485 SET UP menu. For details about
configuring this setting, refer to the operating instructions (PDF).
• Turning on power when this setting is selected causes the RS485 SET UP menu to appear during the
initialisation routine.
 RS485 Communication Parameters (DIP Switch 1)
Configuring DIP Switch 1 as shown below resets communication parameters to their factory default settings. You can
then change the settings as desired.
DIP Switch 1
ON
This setting resets communication parameters to the factory default settings.
1
2
3
4
5
6
7
8
ON
BAUD RATE : 19 200 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
1
2
3
4
5
6
7
8
ON
BAUD RATE : 9 600 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
1
2
3
4
5
6
7
8
ON
ON
BAUD RATE : 4 800 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
1
2
3
4
5
6
7
8
ON
ON
BAUD RATE : 2 400 bit/s, DATA BIT : 8 bit, PARITY CHECK : NONE, STOP BIT : 1 bit
1
2
3
4
5
6
7
8
Perform the following steps to use this setting.
(1) Turn off the camera and use DIP Switch 1 to configure RS485 communication parameters as shown above.
(2) Turn on the camera.
This applies the setting you configured in step (1).
(3) Turn off the camera, use DIP Switch 1 to set the unit number (  pages 13 and 14), and then turn the camera
back on again.