Dip Switch Settings; Communication Parameters (Dip Switch 2) - Panasonic WV-CS580/G Installation Manual

Color cctv camera
Hide thumbs Also See for WV-CS580/G:
Table of Contents

Advertisement

DIP switch settings

Important:
• Before setting up the camera for a configuration where the camera's RS485 data port is used for camera control
(pan, tilt, etc.) by the system controller, the camera's DIP switches must be configured to specify the unit
number and communication parameters.
If DIP switch setting is not performed, the system controller control will not be possible and camera setup will
have to be performed again. Be sure to check the DIP switch settings before setting up the camera.
In a configuration where the camera's RS485 data port is used for camera control (pan, tilt, etc.) by the system
controller, the camera's DIP switches must be configured to specify the unit number and communication parameters.
The camera mounting base needs to be removed to access the DIP switches. See steps 1 and 2 on page 19 for
information about how to remove the camera mounting base.
 Communication Parameters (DIP Switch 2)
The factory default settings are all OFF.
ON
1
2
3
4
Communication
Parameters
Terminator
12
ON
Switch 1: Terminator (Internal Termination Resistance)
Set to ON in the following situations.
• When 1 camera is connected to this unit
• When 2 or more cameras are connected to this unit that works as a
termination
Switches 2 to 4: Communication Parameters
This setting toggles between 2-line and 4-line communication. Use
these switches to select the communication protocol being used.
DIP Switch 1
1
2
3
4
5
6
7
ON
1
2
3
4
4-line Communication
DIP Switch 2
ON
8
1
2
3
4
ON
1
2
3
4
2-line Communication

Advertisement