Hide thumbs Also See for UA-705:

Advertisement

Dear Customer......................................................................2
Preliminary Remarks .............................................................2
Precautions ...........................................................................2
Parts Identification ................................................................3
Symbols ................................................................................4
Using The Monitor ................................................................5
Installing / Changing The Batteries ..................................5
Connecting The Air Hose..................................................5
Selecting The Correct Cuff................................................5
Attaching The Arm Cuff ...................................................6
How To Take Proper Measurements....................................6
Measurement (Operation).................................................6
After Measurement ..........................................................6
Measurements ......................................................................7
Measurement With Storing Data .......................................7
Notes For Proper Measurement ........................................8
Operation Mode ....................................................................9
WHO Classification Indicator .................................................9
Pressure Bar Indicator ...........................................................9
What Is An Irregular Heartbeat? ...........................................10
About Blood Pressure..........................................................10
What Is Blood Pressure?..................................................10
Why Measure Blood Pressure At Home? ..........................10
WHO Blood Pressure Classification .................................10
Blood Pressure Variations.................................................11
Troubleshooting .................................................................11
Maintenance .......................................................................12
Technical Data ....................................................................12
ENGLISH
Contents
English 1

Advertisement

Table of Contents
loading

Summary of Contents for A&D UA-705

  • Page 1: Table Of Contents

    ENGLISH Contents Dear Customer..............2 Preliminary Remarks .............2 Precautions ................2 Parts Identification ..............3 Symbols ................4 Using The Monitor ..............5 Installing / Changing The Batteries ........5 Connecting The Air Hose..........5 Selecting The Correct Cuff..........5 Attaching The Arm Cuff ...........6 How To Take Proper Measurements........6 Measurement (Operation)..........6 After Measurement ............6 Measurements ..............7...
  • Page 2: Dear Customer

    Dear Customer Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. We recommend that you read through this manual carefully before using the device for the first time.
  • Page 3: Parts Identification

    Parts Identification English 3...
  • Page 4: Symbols

    Symbols Symbols Function / Meaning Recommended Action Standby and ON switch. Battery installation guide Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. Measurement is in Indicates measurement is in progress. progress.
  • Page 5: Using The Monitor

    Order No. UA-CUFDBKLA-EC 32 cm to 45 cm Large cuff UA-CUFDBKAU-EC 22 cm to 32 cm Medium cuff Small cuff Arm size: The circumference at the biceps. Note: This UA-705 monitor is NOT designed for using a small cuff. English 5...
  • Page 6: Attaching The Arm Cuff

    Using The Monitor Rolled up shirtsleeve Attaching The Arm Cuff 1. Wrap the cuff around the upper arm, about 2 - 3 cm above the elbow, as Cuff shown. Place the cuff directly against the Air Hose skin, as clothing may cause a faint pulse and result in a measurement error.
  • Page 7: Measurements

    Measurements Measurement With Storing Data 1. Place the cuff on the arm (preferably the left arm). Sit quietly during measurement. 2. Press the button. START The buzzer sounds and the average blood pressures and the WHO classification and last data number are displayed briefly. When the "...
  • Page 8: Notes For Proper Measurement

    environment, will display. 7. Turning the power off Press the button to turn the power off. START The device will be in standby mode. 8. Subsequent measurements If a subsequent measurement is required, turn off the power and turn it on again.
  • Page 9: Operation Mode

    Operation Mode ( Refer to page 7) Measurement with storing data Press the button. Blood pressure is measured and data is stored START within the device. The device can store the last thirty sets of data for each button. Recalling data Press and hold Press and hold the button to recall the data.
  • Page 10: What Is An Irregular Heartbeat

    What Is An Irregular Heartbeat? Model UA-705 blood pressure monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement.
  • Page 11: Blood Pressure Variations

    Blood Pressure Variations An individual’s blood pressure varies greatly on a daily and seasonal basis. It may vary by 30 to 50 mmHg due to various conditions during the day. In hypertensive individual variations are even more pronounced. Normally, the blood pressure rises while at work or play and falls to its lowest levels during sleep.
  • Page 12: Maintenance

    2 years, to ensure proper functioning and accuracy. Please contact either your authorized dealer or A&D for maintenance. Technical Data Type UA-705 Measurement method Oscillometric measurement Measurement range Pressure: 20 - 280 mmHg...