Maintenance
6. Replace the battery caps, and leave them in place
while charging.
7. Unplug the machine connector from the battery.
FOR SAFETY: When charging, connect the charger
to the batteries before connecting the charger to
the AC wall outlet. Never connect the charger to the
AC wall outlet first. Hazardous sparks may result.
8. Plug the charger connector into the battery
connector. Connect the charger AC plug to a wall
outlet. The charger gauge should indicate that the
batteries are charging.
9. When the batteries are fully charged, disconnect
the charger from the AC wall outlet, then discon-
nect the charger from the batteries.
10. Connect the machine to the battery connector.
11. Check the electrolyte level. It should be up to the
indicator ring. If necessary, add distilled water.
12. Lower recovery tank by safely disengaging the
prop rod latch and slowly lowering. Replace the
hose and "Y" tube connection. Replace front
cover.
28

Changing Batteries

Stop the machine in a clean area next to the charger.
Turn off machine.
FOR SAFETY: Before leaving or servicing the
machine; stop on level surface, turn off machine
and remove key.
1. Disconnect machine from battery pack.
2. Raise recovery tank and engage prop rod latch.
3. Disconnect main positive lead and secure cable
terminals away from batteries.
4. Loosen both terminals on each jumper cable and
remove one at a time.
5. Prepare a suitable site to place the batteries.
6. Attach suitable battery lifting device and lift
batteries from the machine.
Batteries are a potential environmental hazard.
Consult your battery supplier for safe disposal
methods.
RED
RED
RED
86292200 COMMODORE DUO
-
BLK
-
BLK
-
BLK