Battery Charger Programming

NOTE: For machines equipped with optional on-
board charger. When replacing batteries, charger
programming changes may be required. If replacing
batteries with same type, (e.g. maintenance free
batteries with maintenance free) no programming is
required. When batteries with different type
(e.g.maintenance free with wet cell), programming
changes are required. Failure to make programming
changes may lead to reduced battery life.
Switching From Wet Cell to Maintenance
Free Batteries
Program charger from normal mode (red LED flashes)
to alternate mode (Red and green LED's flash):
1. Disconnect battery charger from outlet.
2. Connect (+) wire from EZlamp to (+) charger
battery cable.
3. Connect AC cord to outlet. All LED's should be on.
NOTE: If red and green LED's do not flash, repeat
steps 1 and 2.
4. Wait 5 seconds, disconnect wires and unplug
charger.
5. Programming is complete.
Switching From Maintenance Free to Wet
Cell Batteries
Program charger from alternate mode (Red and green
LED's flash) to normal mode (red LED flashes):
1. Disconnect battery charger from outlet.
1. Connect (+) wire from EZlamp to (+) charger
battery cable.
2. Connect AC cord to outlet. Red LED should be on.
NOTE: If Red LED light does not flash, repeat steps 1
and 2.
3. Wait 5 seconds, disconnect wires and unplug
charger.
4. Programming is complete.
NOTE: Battery Charger must be approved to
60335-2-29 standard.