Direct Spark Ignition Detail - Garland moisture+ MP-GD-10-S Service Manual

Garland oven user manual
Hide thumbs Also See for moisture+ MP-GD-10-S:
Table of Contents

Advertisement

TESTING & TROUBLESHOOTING

Direct Spark Ignition Detail

MPO Direct Spark Ignition Specifications and Module Box Connections
Manufacturer
Vendor Part #
Ignition Type
High Voltage Cable Wire
Ignition Source
Maximum Cable Length
Flame Detection Means
Flame Detection Types
Minimum Flame Current
Flame Failure
Response Time
Spark Gap
Ignition Retrials
Safety Times
Waiting Times
Interpurge
Loss Of Flame Signal Retrials
Operation Current
Contact Rating (MV)
Ambient Operating And
Storage Fluttered
Humidity
Wire Connections
Spark Options
Page 54
JOHNSON CONTROLS INC .
G760BAD-1
Direct Spark
Stranded
High Voltage Spark
48" (1,220mm)
Flame Rectification
Remote Sensing
0 .3 Microampere
0 .8 Seconds Maximum
0 .1" (2 .5mm)
3
4 Seconds
0 Seconds
30 Seconds
4 (Five Total Ignition Attempts)
24 VAC, 50/60 HZ, Nominal, 0 .2A
Nominal + Main Valve
2A Continuous, 5A Inrush
-40 to 158 °F (-40 to 70°C)
95% RH non-condensing
RAJAH Connector
GROUND
5
LED
THS 2
M.V. 3
SENSE 4
Part # MPSM07 (03/24/08)