COMPONENT IDENTIFICATION

Cavity Temperature Controls

Service Overview
Spritzer (Water Inlet) –
Purpose: This temperature switch assures water injection
will not be available below a cavity temperature that
would allow excessive puddle buildup on the cavity floor .
The switch will close at a temperature of 225°F on rise .
This low, but slightly above superheat value of water
temperature will enable a preference of low temperature
cooking .
Spritzer
Temperature
Control
Part # MPSM07 (03/24/08)
NOTE: Water can only be injected
after the oven has preheated to at
least 225°F (107°C) .
Control Compartment Ambient Temperature –
Purpose: This control will automatically run the cooling fan
in the control compartment if the temperature reaches,
or exceeds 150°F . This function will assure maximum
air extraction of hot ambient control compartment air
during continuous operation, and intake of cooler outside
ambient air .
Cooling
Fan
Control