Chapter 6
Installing the IPS 4345 and IPS 4360
Step 8
Power on the appliance.
Initialize the appliance.
Step 9
Install the most recent Cisco IPS software. You are now ready to configure intrusion prevention on the
Step 10
appliance.
For More Information

Removing and Installing the Power Supply

This section describes the AC and DC power supplies and how to install and remove them. It contains
the following topics:

AC Power Supply in V01 and V02 Chassis

The Cisco IPS 4300 series sensors with the AC power supply can restore the previous power state of the
system if AC power is lost. Earlier IPS 4300s (V01) require you to turn on the power with the power
switch. Newer IPS 4300s (V02) automatically turn on when you plug in the power cable. To determine
your version, do one of the following:
The V01 chassis has the following limitations (these limitations do not apply to the V02 chassis):
OL-24002-01
For more information about ESD, see
For the procedure for using the setup command to initialize the appliance, see
"Initializing the Sensor."
For the procedure for obtaining IPS software, see
For the procedures for configuring intrusion prevention on your sensor, refer to the following
documents:
Cisco Intrusion Prevention System Device Manager Configuration Guide for IPS 7.1
Cisco Intrusion Prevention System Manager Express Configuration Guide for IPS 7.1
Cisco Intrusion Prevention System Sensor CLI Configuration Guide for IPS 7.1
AC Power Supply in V01 and V02 Chassis, page 6-15
Understanding the Power Supplies, page 6-16
Removing and Installing the AC Power Supply, page 6-18
Installing DC Input Power, page 6-21
Removing and Installing the DC Power Supply, page 6-26
At the CLI, enter the show inventory command and look for V01 or V02 in the output.
On the back of the chassis, look at the VID PID label for V01 or V02.
The sensor requires 50 seconds from the time that AC power is applied before the power state can
be updated and stored. This means that any changes to the power state within the first 50 seconds of
applying AC power will not be observed if AC power is removed within that time.