Slab Mounting Details; Notice To Riggers; Suggested Rigging For Units Without Base Rail; Suggested Rigging For Units With Optional Base Rail - Bryant 588A Installation, Start-Up And Service Instructions Manual

Single package gas heating/ electric cooling units
Hide thumbs Also See for 588A:
Table of Contents

Advertisement

Fig. 11 — Slab Mounting Details

NOTICE TO RIGGERS

Hook rigging shackles through holes in lifting brackets, as shown in De-
tail ''A.'' Lifting brackets to be centered around the unit center of gravity.
Use wooden top skid when rigging, to prevent rigging straps from dam-
aging unit.
CAUTION:
All panels must be in place when rigging.
UNIT
MAX
A
588A
WEIGHT
Size
lb
kg
in.
018
332
150
024
375
170
030
384
174
036
408
185
49.4
042
447
203
048
486
220
060
525
238
UNIT
589A
024
405
184
030
408
185
036
438
199
49.4
042
463
210
048
494
224
060
525
238
Fig. 12 — Suggested Rigging for Units Without
Base Rail
B
C
mm
in.
mm
in.
24.3
618
24.85
22.4
570
24.85
22.3
565
24.85
1255
22.0
559
24.85
22.5
571
28.85
21.0
533
34.85
21.5
545
34.85
22.8
579
28.9
22.4
569
28.9
22.4
569
28.9
1255
22.8
579
34.9
21.1
536
34.9
21.5
545
34.9
Hook rigging shackles through holes in lifting brackets, as shown in De-
tail ''A.'' Lifting brackets to be centered around the unit center of gravity.
Use wood top skid when rigging, to prevent rigging straps from damag-
ing unit. Remove 4 screws to slide wood support through rectangular
hole in rail.
CAUTION:
UNIT
MAX
588A
WEIGHT
Size
lb
018
320
024
363
030
380
036
396
042
435
048
474
060
513
UNIT
589A
024
393
030
396
036
426
042
451
048
482
060
513
Fig. 13 — Suggested Rigging for Units With
A. Units Without Base Rail
If accessory rigging brackets are to be used for rigging, in-
stall them as follows:
WARNING: Secure screws and paint protectors sol-
idly against unit basepan to hold lifting brackets in
position.
Never use lifting brackets when the temperature is be-
low −10 F.
mm
Never exceed 200 lbs per bracket of lifting force.
631
631
Never use lifting brackets for lifting other models of air-
631
conditioning units.
631
733
Lifting point should be directly over the unit center of
885
gravity.
885
1. Position brackets as close to the corners of unit as pos-
733
sible. Be sure brackets are well outside of center of grav-
733
ity. (See Fig. 2, 4, 6, 8, and 12.).
733
885
2. Position paint protectors and foam strips between screws
885
and painted surface of unit. Tighten screws until they
885
make contact with the paint protectors.
3. Secure device or hook of sufficient strength to hole in
bracket as shown in detail ''A'' of Fig. 12.
4. If wood top is available, use it for a spreader bar to pre-
vent straps from damaging unit. If wood top is not avail-
able, use spreader bars of sufficient length.
—12—
NOTICE TO RIGGERS
All panels must be in place when rigging.
A
B
kg
in.
mm
in.
145
24.4
165
22.6
172
22.5
180
49.4
1255
22.2
197
22.6
215
21.2
233
21.6
178
22.9
180
22.6
193
22.5
49.4
1255
205
22.9
219
21.3
233
21.6
Optional Base Rail
C
mm
in.
mm
619
28.2
715
574
28.2
715
571
28.2
715
563
28.2
715
574
32.2
816
538
38.2
969
549
38.2
969
582
32.2
816
574
32.2
816
571
32.2
816
582
38.2
969
540
38.2
969
549
38.2
969

Hide quick links: