Options; Advance Planning; Ductwork Arrangement - GE Monogram ZEW145V Installation Manual

Component cooktop system
Table of Contents

Advertisement

Ductwork
Conlponent
Cooktop
_vstem
Through Floor Between Joists
Through Floor & Under Joists
Multiple
cooktops
and downdrafl
vent units
may be used in a single
arrangement.
• Plan the route
for venting
exhaust
to the
outdoors.
• Ductwork
nmst
be vented
to outdoors
- never
to a crawl space,
attic or other
enclosed
space.
• Duct should
be located
between
floorjoists
or
wall studs
whenever
possible.
• Blower
and motor
assembly
can be installed
on an outside
wall. JXBC55
optional
outdoor
cover accessory
is required
and nmst
be
ordered
with each
downdraft
venting
unit.
• Every downdraft
vent and downdraft
grill
must
have it's own, separate
duct run.
Inside Wall
To Roof
Direct To Outdoors
With JXBC55Mounted
On Outside Wall
Ductwork
Advance
Planning
• Use tile shortest
and straightest
duct run
possible.
-Duct
run for Downdraft
Grill Component,
ZEW166Y,
should
not exceed
equivalent
length
of 100 feet.
Duct
run for Downdraft
Vent, ZEW176Y,
should
not exceed
equivalent
length
of
150 feet.
-Refer
to "Duct Fittings"
chart
to calculate
equivalent
length
for various
duct
configurations.
• The downdrafl
blower
system
is designed
for
use with 3-1/4"
x 10" ductwork.
It can be
transitioned
to 6" round.
• Ductwork
MUST
be vented
to the outside
never
into a crawl space, attic or other
enclosed
space.
Opdonal
Ductwork
Arrangement
6" PVC duct
should
be used when
installing
under
a concrete
slab.
• Use recommended
wall caps with damper.
Do not use laundry
type wall caps.
• Ductwork
nmst
be vented
to the outside.
• Each cooktop
blower
system
requires
a
separate
duct system.
NOTE: Localbuilding code must be followed for installation and in
specifying approved type and schedule of PVCduct used,
1o