Reliability; Environmental; Environmental Specifications - Intel D53427RKE Specification

Nuc board
Table of Contents

Advertisement

Intel NUC D53427RKE Technical Product Specification
2.8

Reliability

The Mean Time Between Failures (MTBF) prediction is calculated using component and
subassembly random failure rates. The calculation is based on the Telcordia SR-332
Issue 2, Method I, Case 3, 55 ºC ambient. The MTBF prediction is used to estimate
repair rates and spare parts requirements. The MTBF for the board is 71,537 hours.
2.9

Environmental

Table 21 lists the environmental specifications for the board.
Table 21. Environmental Specifications
Parameter
Temperature
Non-Operating
Operating
Shock
Unpackaged
Packaged
Vibration
Unpackaged
Packaged
60
Specification
-40 °C to +60 °C
0 °C to +50 °C
50 g trapezoidal waveform
Velocity change of 170 inches/s²
Half sine 2 millisecond
Product Weight (pounds)
<20
21-40
41-80
81-100
5 Hz to 20 Hz: 0.01 g² Hz sloping up to 0.02 g² Hz
20 Hz to 500 Hz: 0.02 g² Hz (flat)
5 Hz to 40 Hz: 0.015 g² Hz (flat)
40 Hz to 500 Hz: 0.015 g² Hz sloping down to 0.00015 g² Hz
Free Fall (inches)
Velocity Change (inches/s²)
36
167
30
152
24
136
18
118

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc53427hye