Reliability; Environmental; Environmental Specifications - Intel NUC5i5MYBE Product Specification

Nuc board
Table of Contents

Advertisement

Intel NUC Board NUC5i5MYBE Technical Product Specification
2.8

Reliability

The Mean Time Between Failures (MTBF) prediction is calculated using component and
subassembly random failure rates. The calculation is based on the Telcordia SR-332 Issue 2,
Method I, Case 3, 55 ºC ambient. The MTBF prediction is used to estimate repair rates and spare
parts requirements. The MTBF for Intel NUC Board NUC5i5MYBE is 61,825 hours.
2.9

Environmental

Table 38 lists the environmental specifications for the board.
Table 38. Environmental Specifications
Parameter
Temperature
Non-Operating
Operating
Shock
Unpackaged
Packaged
Vibration
Unpackaged
Packaged
Note: Before attempting to operate this board, the overall temperature of the board must be above the minimum
operating temperature specified. It is recommended that the board temperature be at least room temperature
before attempting to power on the board. The operating and non-operating environment must avoid condensing
humidity.
74
Specification
-40 °C to +60 °C
0 °C to +50 °C
The operating temperature of the board may be determined by measuring the air
temperature from the junction of the heatsink fins and fan, next to the attachment screw,
in a closed chassis, while the system is in operation.
50 g trapezoidal waveform
Velocity change of 170 inches/s²
Half sine 2 millisecond
Product Weight (pounds)
<20
21-40
41-80
81-100
5 Hz to 20 Hz: 0.01 g² Hz sloping up to 0.02 g² Hz
20 Hz to 500 Hz: 0.02 g² Hz (flat)
5 Hz to 40 Hz: 0.015 g² Hz (flat)
40 Hz to 500 Hz: 0.015 g² Hz sloping down to 0.00015 g² Hz
Free Fall (inches)
Velocity Change (inches/s²)
36
167
30
152
24
136
18
118