(4) Current Requirements and Power Dissipation
Table 1.3 lists the current and power dissipation (typical).
Spin up (*1)
Idle
R/W (on track) (*2)
Seek (*5)
Standby
Sleep
Energy
Efficiency (*4)
*1
Current at starting spindle motor.
*2
Current and power level when the operation (command) that accompanies a
transfer of 63 sectors is executed 3 times in 100 ms
*3
Power requirements reflect nominal values for +5 V power.
*4
Energy efficiency based on the Law concerning the Rational Use of Energy
indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)
*5
The seek average current is specified based on three operations per 100
msec.
(5) Current fluctuation (Typ.) at +5 V when power is turned on
C141-E192-01EN
Table 1.3 Current and power dissipation
Typical RMS Current
MHT Series
0.9 A
130 mA
Read 400 mA / Write 420mA
460 mA
50 mA
20 mA
1.3 Power Requirements
Typical Power (*3)
MHT Series
4.5 W
0.65 W
Read 2.0 W / Write 2.1 W
2.3 W
0.25 W
0.1 W
0.008 W/GB
(rank E / MHT2080AT)
0.011 W/GB
(rank E / MHT2060AT)
0.011 W/GB
(rank E / MHT2040AT)
0.022 W/GB
(rank D / MHT2030AT)
0.022 W/GB
(rank D / MHT2020AT)