Fujitsu MHT2020AT Product Manual page 103

Fujitsu computer drive user manual
Table of Contents

Advertisement

At command issuance (I/O registers setting contents)
1F7
(CM)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
*1
If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.
(9) RECALIBRATE (X'10' to X'1F')
This command performs the calibration. Upon receipt of this command, the
device sets BSY bit of the Status register and performs a calibration. When the
device completes the calibration, the device updates the Status register, clears the
BSY bit, and generates an interrupt.
This command can be issued in the LBA mode.
C141-E192-01EN
0
0
1
1
x
L
x
DV
Start cylinder No. [MSB] / LBA
Start cylinder No. [LSB] / LBA
Start sector No. / LBA [LSB]
Transfer sector count
xx
Status information
x
L
x
DV
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No. / LBA [LSB]
00 (*1)
Error information
5.3 Host Commands
1
1
0
0
Start head No. / LBA
[MSB]
End head No. / LBA [MSB]
5-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mht2060atMht2030atMht2080atMht2040at

Table of Contents