Fujitsu MHS2020AT Maintenance Manual

Hide thumbs Also See for MHS2020AT:

Advertisement

Quick Links

C141-F059-01EN
MHS2060AT, MHS2040AT
MHS2030AT, MHS2020AT
DISK DRIVES
MAINTENANCE MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu MHS2020AT

  • Page 1 C141-F059-01EN MHS2060AT, MHS2040AT MHS2030AT, MHS2020AT DISK DRIVES MAINTENANCE MANUAL...
  • Page 2 “Important Alert Items” in this manual. Keep this manual handy, and keep it carefully. FUJITSU makes every effort to prevent users and bystanders from being injured or from suffering damage to their property. Use the product according to this manual.
  • Page 3: Revision History

    Revision History (1/1) Edition Date Revised section (*1) Details (Added/Deleted/Altered) 2002-07-15 — — *1 Section(s) with asterisk (*) refer to the previous edition when those were deleted. C141-F059-01EN...
  • Page 4 This page is intentionally left blank.
  • Page 5 Preface This manual describes the MHS2060AT, MHS2040AT, MHS2030AT and MHS2020AT 2.5-inch hard disk drives with a built-in controller that is compatible with the ATA interface. This manual explains, in detail, how to maintain the disk drives. This manual assumes that users have a basic knowledge of hard disk drives and their application in computer systems.
  • Page 6: Operating Environment

    “Disk drive defects” refers to defects that involve adjustment, repair, or replacement. Fujitsu is not liable for any other disk drive defects, such as those caused by user misoperation or mishandling, inappropriate operating environments, defects in the power supply or cable, problems of the host system, or other causes outside the disk drive.
  • Page 7: Important Alert Items

    Important Alert Items Important Alert Messages The important alert messages in this manual are as follows: This manual uses the key alert messages given below. The following manual also contains notes on safety precautions: A hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly.
  • Page 8 Data corruption When asking for repair, save all data stored in the disk drive beforehand. Fujitsu Limited is not responsible for any loss of data during service and repair. Device damage The disk enclosure must never to be opened in the field.
  • Page 9 Important Alert Items Task Alert message Page Maintenance Damage or Device damage 1. Perform any removal after the system power is completely disconnected. The cable must not be disconnected and the screws that attach the drive must not be removed with the power ON. 2.
  • Page 10 This page is intentionally left blank.
  • Page 11: Manual Organization

    Manual Organization MHS2060AT, MHS2040AT 1. Device Overview MHS2030AT, MHS2020AT 2. Device Configuration 3. Installation Conditions DISK DRIVES 4. Theory of Device Operation PRODUCT MANUAL 5. Interface (C141-E171) 6. Operations MHS2060AT, MHS2040AT 1. Maintenance and Diagnosis MHS2030AT, MHS2020AT 2. Removal and Replacement Procedure DISK DRIVES MAINTENANCE MANUAL <This manual>...
  • Page 12 This page is intentionally left blank.
  • Page 13: Table Of Contents

    Contents CHAPTER 1 Maintenance and Diagnosis ............. 1-1 Maintenance ....................1-2 1.1.1 Rules for maintenance................1-2 1.1.2 Maintenance requirements ..............1-3 1.1.3 Maintenance levels................1-5 1.1.4 Disk drive revision number..............1-6 1.1.5 Tools and test equipment ..............1-8 1.1.6 Self-diagnostics..................1-8 1.1.7 Test......................1-8 Operation Confirmation ................1-10 1.2.1 Operation test ..................1-10 1.2.2 Diagnostic test..................1-11...
  • Page 14 Contents Illustrations Figures Figure 1.1 Disk drive revision number label Figure 1.2 Display of disk drive revision number Figure 1.3 Test flowchart 1-9 Tables Table 1.1 Status register contents 1-10 Table 1.2 Disposition for error register contents 1-10 Table 1.3 System level and field troubleshooting 1-12 Table 2.1...
  • Page 15: Chapter 1 Maintenance And Diagnosis

    CHAPTER 1 Maintenance and Diagnosis Maintenance Operation Confirmation Troubleshooting Procedure This chapter describes the maintenance, diagnosis, operation check, and troubleshooting of the disk drive. The following are explained: Rules for regular maintenance and troubleshooting Display of maintenance level (field and factory) Display of machine revision number and number change in the field Tools and test devices needed for each maintenance level Standard testing for each maintenance level...
  • Page 16: Maintenance

    1.1 Maintenance Maintenance and Diagnosis Maintenance 1.1.1 Rules for maintenance The following cautions must be observed to prevent injury during troubleshooting or maintenance. Static, Damage Don’t install or remove a PCA or connect or disconnect a cable or connector plug when the drive is powered. This may give you an electric shock.
  • Page 17: Maintenance Requirements

    The PCA and the DE cannot be replaced separately in the field. Replace the whole disk drive. (4) Service system and repair Fujitsu Limited has a disk drive service system and repair facility. When making a request for repair or parts replacement, you should provide related information usually including:...
  • Page 18 1.1 Maintenance Maintenance and Diagnosis Data corruption When asking for repair, save all data stored in the disk drive beforehand. Fujitsu Limited is not responsible for any loss of data during service and repair. (5) Notes on handling General notes a) Vibrations and shocks more severe than allowed will cause fatal damage to the device so be very careful.
  • Page 19: Maintenance Levels

    1.1 Maintenance b) It is recommended that you use the shock absorption cushion material and packaging that contained the device when it was delivered by Fujitsu. If the same packaging material cannot be used, use a shock absorbent box that will transmit shocks directly to the device. When using this type of box, adequately protect the PCA surface and interface connector section.
  • Page 20: Disk Drive Revision Number

    First 2-digit indicates a firmware code and rest 2-digit indicates its revision. Note: For a change of revision number after delivery, Fujitsu issues a “Change Request/Notice” and the disk drive revision number after the change. When a change is made at the user site, the revision number level should be changed as described above.
  • Page 21: Figure 1.2 Display Of Disk Drive Revision Number

    Maintenance and Diagnosis 1.1 Maintenance Revision number mark when delivered A2 Revision Revision number change in the field A3 Revision Figure 1.2 Display of disk drive revision number C141-F059-01EN...
  • Page 22: Tools And Test Equipment

    1.1 Maintenance Maintenance and Diagnosis 1.1.5 Tools and test equipment At the field maintenance level, only ordinary hand tools are required for troubleshooting and repairing the disk drive. Special tools and test equipment is not required. Factory level tools and test equipment are beyond the scope of this manual. 1.1.6 Self-diagnostics The disk drive has the following self-diagnostics.
  • Page 23: Figure 1.3 Test Flowchart

    Maintenance and Diagnosis 1.1 Maintenance Start Check the host system (Table 1.1) Operation test with the Analyze the system System normal? host computer or test related failure equipment Disk drive replacement or repair Test acceptable? Disk drive normal? Continue with the operation Diagnostic test with the host computer or...
  • Page 24: Operation Confirmation

    1.2 Operation Confirmation Maintenance and Diagnosis Table 1.1 Status register contents Status bit Contents BIT0=1 Shown in Table 1.2 BIT1, 2 Normal. BIT3=1 (1) Check whether vibration is transmitted because of the way the disk drive is mounted. BIT4=1 (2) Check the power, cable, and connector. BIT5=1 (3) If it is concluded that the disk drive is the cause, replace the disk drive.
  • Page 25: Diagnostic Test

    Maintenance and Diagnosis 1.3 Troubleshooting Procedure To troubleshoot the failure reported in the test at this level, accurately reproduce the condition that caused the failure. Then, by replacing the disk drive, try to separate the fault from the other sections of the disk drive host system. 1.2.2 Diagnostic test The diagnostic test is used to separate a confirmed disk drive failure to a disk drive subassembly or to check the disk drive performance.
  • Page 26: Table 1.3 System Level And Field Troubleshooting

    1.3 Troubleshooting Procedure Maintenance and Diagnosis Table 1.3 System level and field troubleshooting Check to be made Recommended work DC power voltage Confirm that the DC power voltage is within 5% of the standard value. level When measured at pins 41 and 42 of the power supply connector, the +5 VDC must be 4.75 to 5.25 VDC.
  • Page 27: Troubleshooting At Factory

    Maintenance and Diagnosis 1.3 Troubleshooting Procedure 1.3.3 Troubleshooting at factory When the trouble is recovered by replacing the drive at field (Subsection 1.3.2), troubleshoot the replaced drive to isolate the trouble to the subassembly parts. To shorten the troubleshooting time and repairing time, gather the data, such as environmental data and other information, from the user and then return the failed drive to the factory with the media defect list to repair.
  • Page 28 This page is intentionally left blank...
  • Page 29: Chapter 2 Removal And Replacement Procedure

    CHAPTER 2 Removal and Replacement Procedure Spare Parts Disk Drive Removal This chapter explains the procedure for removing and replacing the disk drive. It is assumed that the reader has a thorough knowledge of replacing the complete disk drive and replacing the power-interface cable. When carrying out these procedures, note the following items.
  • Page 30: Spare Parts

    2.1 Spare Parts Removal and Replacement Procedure Spare Parts See Table 2.1 for the model and parts numbers to order the replacement disk drive. Table 2.1 Model and parts numbers Model Part number Formatted Mounting screw capacity MHS2060AT CA06272-B042 60 GB MHS2040AT CA06272- 40 GB...
  • Page 31: Acronyms And Abbreviations

    Acronyms and Abbreviations ABRT Aborted command Host adapter Alternating current Hard disk drive Automatic idle control AMNF Address mark not found AT attachment IDNF ID not found American Wire Gauge IRQ14 Interrupt request 14 Bad block detected Light emitting diode BIOS Basic input-output system Mega-byte...
  • Page 32 Acronyms and Abbreviations Uncorrectable ECC error Voice coil motor AB-2 C141-F059-01EN...
  • Page 33 Index Dampproof packaging 1-5 Notes general 1-4 Delivery 1-5 on handling 1-4 revision number marking 1-6 Diagnostic test 1-11 Disk drive replaced, troubleshooting 1-11 Offline self-diagnostics 1-8 replacement 1-5 Operation revision number 1-6 configuration 1-10 revision number label 1-6 test 1-10 Disposition for error register contents 1-10 Packaging 1-4 Exchangable parts in field 1-3...
  • Page 34 Index Troubleshooting at factory 1-13 disk drive replaced in field 1-11 procedure 1-11 system level and field 1-12 Unpacking 1-4 IN-2 C141-F059-01EN...
  • Page 35 Technical level: Too high Appropriate Too low Overall rating of this publication: Good Fair Poor FOR FUJITSU USE Overseas office: Person in charge: Note) Local representative should pass this form to the section in charge of distribution in FUJITSU. Reply...
  • Page 36 This page is intentionally left blank...
  • Page 38 This page is intentionally left blank...