2.5.6.3

Specifying Displaying Trace Data Start

The data display start position in the trace buffer can be specified by inputting a step
number or frame number using the SHOW TRACE command. The data display range can
also be specified.
■ Specifying Displaying Trace Data Start
Specify the data display start position in the trace buffer by inputting a step number or frame number using
the SHOW TRACE command. The data display range can also be specified.
[Example]
>SHOW TRACE/RAWDATA -6
>SHOW TRACE/RAWDATA -6..0
>SHOW TRACE -6
>SHOW TRACE -6..0
CHAPTER 2 DEPENDENCE FUNCTIONS
; Start displaying from frame -6
; Display from frame -6 to frame 0
; Start displaying from step -6
; Displays from step -6 to step 0