b.
Remove the hinge covers (2). The hinge covers are available using spare part number
650462-001.
7.
If it is necessary to replace the display panel:
a.
Remove the following screws that secure the display panel to the display enclosure:
●
Two Phillips PM2.5×3.5 broad head screws (1) on the top edge of the display panel
●
Four Phillips PM2.5×4.5 screws (2) on the hinges
●
Two Phillips PM2.0×3.0 screws (3) on the bottom edge of the display panel
b.
Disconnect the webcam cable (1) from the webcam module.
c.
Release the tabs (2) on the left and right sides of the display panel.
Component replacement procedures