Frymaster LOV BIELA14 Service And Parts Manual page 38

Gen ii electric fryer
Hide thumbs Also See for LOV BIELA14:
Table of Contents

Advertisement

Problem
M3000 display shows
ENERGY
MISCONFIGURED
M3000 display shows
EXCEPTION
ERROR with the
description on the right.
M3000 displays
SERVICE
REQUIRED followed
by the error.
M3000 display is in
wrong temperature
scale (Fahrenheit or
Celsius).
M3000 displays
CHANGE FILTER
PAD.
M3000 display shows
INSERT pan.
M3000 display shows
hot-hi-1.
M3000 display shows
HI-LIMIT.
M3000 display shows
low temp
alternating with MLT-
CYCL.
M3000 display shows
ERROR RM SDCRD
Probable Causes
Wrong energy type selected in setup.
An error has occurred.
An error has occurred.
Incorrect display option programmed.
Filter error has occurred, filter pad
clogged, 24 hour filter pad change prompt
has occurred or change filter pad was
ignored on a prior prompt.
A. Filter pan is not fully inserted into fryer.
B. Missing filter pan magnet.
C. Defective filter pan switch.
Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF
(202ºC).
Computer in high-limit test mode.
Frypot temperature is between 180°F
(82°C).
Defective SD Card
Press 1234 to enter setup and set energy type
for electric.
Press 1234 to enter setup and reconfigure the
computer.
Press YES to silence alarm. The error is
displayed three times. See list of issues in
section 1.14.3. Fix issue. The computer
displays SYSTEM ERROR FIXED?
YES/NO. Press YES. Computer displays
ENTER CODE. Enter 1111 to clear error
code. Pressing NO will allow the fryer to
cook but the error will be redisplayed every
15 minutes.
See section 1.14.2 on page 1-33 to change
temperature scale.
Change the filter pad and ensure the filter pan
has been removed from the fryer for a
minimum of 30 seconds.
Do NOT ignore CHANGE FILTER
PAD prompts.
A. Pull filter pan out and fully reinsert into
fryer.
B. Ensure the filter pan magnet is in place
and if missing replace.
C. If the filter pan magnet is fully against
the switch and computer continues to
display INSERT
possibly defective.
This in an indication of a malfunction in the
temperature control circuitry, including a
failure of the high-limit thermostat.
This is displayed only during a test of the
high-limit circuit and indicates that the high-
limit has opened properly.
This display is normal when the fryer is first
turned on while in the melt cycle mode. To
bypass the melt cycle press and hold either #1
or #2 cook button under the LCD display
until a chirp is heard. The computer displays
EXIT MELT alternating with YES NO.
Press the #1 YES button to exit melt. If the
display continues, the fryer is not heating.
Replace card with another card.
1-31
Corrective Action
pan, switch is