Frymaster 8196203 Installation, Operation, Service, And Parts Manual page 35

Navy surface ship electric fryers
Table of Contents

Advertisement

2. On dual-vat fryers, and on full-vat fryers where the temperature probe is attached to the element
being replaced, disconnect the wire harness containing the probe wiring. Using a pin pusher,
disconnect the probe wires from the 12-pin connector C-6.
3. In the rear of the fryer directly behind the frypot disconnect the 6-pin connector for the left
element (as viewed from the front of the fryer) or the 9-pin connector for the right element.
Press in on the tabs on each side of the connector while pulling outward on the free end to extend
the connector and release the element leads (see photo below). Pull the leads out of the
connector and out of the wire sleeving.
4. Raise the element to the full up position and support the elements.
5. Remove the hex head screws and nuts that secure the element to the tube assembly and pull the
element out of the frypot. NOTE: Full-vat elements consist of two dual-vat elements clamped
together. For full-vat units, remove the element clamps before removing the nuts and screws that
secure the element to the tube assembly.
6. If applicable, recover the probe bracket and probe from the element being replaced and install
them on the replacement element, then install the replacement element in the frypot, securing it
with the nuts and screws removed in Step 5 to the tube assembly ensuring the gasket is between
the tube and element assembly.
7. Route the element leads through the element tube assembly and into the wire sleeving to prevent
chafing. Ensure that the wire sleeving is routed back through the Heyco bushing keeping it clear
from the lift springs. Also ensure that the wire sleeving extends into the tube assembly to protect
the edge of the tube assembly from chafing the wires. Press the pins into the connector in
accordance with the diagram below, and then close the connector to lock the leads in place.
NOTE: It is critical that the wires be routed through the sleeving to prevent chafing.
Index Marker marks
Position 1
3
2
1
6
5
4
6
5
6L
5L
4L
3L
2L
1L
4R
R
R
7-5
Note: Liquid
resistant
seals.
3
2
1
6
5
4
9
8
7
2
3R
1R
R

Advertisement

Table of Contents
loading

This manual is also suitable for:

H14scH17scH22scFph17sc series

Table of Contents